HT1381-8SOPLF HOLTEK, HT1381-8SOPLF Datasheet - Page 5

IC, TIMEKEEPER, SERIAL, SMD, SOP8

HT1381-8SOPLF

Manufacturer Part Number
HT1381-8SOPLF
Description
IC, TIMEKEEPER, SERIAL, SMD, SOP8
Manufacturer
HOLTEK
Datasheet

Specifications of HT1381-8SOPLF

Clock Format
HH
Clock Ic Type
Timekeeper
Supply Voltage Range
2V To 5.5V
Digital Ic Case Style
SOP
No. Of Pins
8
Operating Temperature Range
0°C To +70°C
Date Format
DD
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The following table shows the register address and its data format:
R/W signal
The LSB of the Command Byte determines
whether the data in the register be read or be
written to.
When it is set as ²0² means that a write cycle is
to take place otherwise this chip will be set into
the read mode.
CH:
WP:
Bit 7 of Reg2:
Bit 5 of Reg2:
Register
Seconds
Minutes
Hours
Date
Month
Day
Year
Write
Protect
Name
Clock Halt bit
CH=0 oscillator enabled
CH=1 oscillator disabled
Write protect bit
WP=0 register data can be written in
WP=1 register data can not be written in
Range
00~59
00~59
01~12
00~23
01~31
01~12
01~07
00~99
00~80
Data
12/24 mode flag
bit 7=1, 12-hour mode
bit 7=0, 24-hour mode
AM/PM mode defined
AP=1 PM mode
AP=0 AM mode
12\
WP
CH
D7 D6 D5
24
0
0
0
0
10 YEAR
0
0
0
0
0
10 SEC
10 MIN
Register Definition
10 DATE
AP
10
0
0
ALWAYS ZERO
10M
HR
HR
D4
0
D3 D2 D1 D0
5
MONTH
HOUR
DATE
YEAR
A0~A2
A0 to A2 of the Command Byte is used to specify
which registers are to be accessed. There are
eight registers used to control the month data,
etc., and each of these registers have to be set as
a write cycle in the initial time.
Burst mode
When the Command Byte is 10111110 (or
10111111), the HT1380/HT1381 is configured in
burst mode. In this mode the eight clock/calen-
dar registers can be written (or read) in series,
starting with bit 0 of register address 0 (see the
timing on the next page).
Test mode
When the Command Byte is set as 1001xxx1,
HT1380/HT1381 is configured in test mode.
The test mode is used by Holtek only for testing
purposes. If used generally, unpredictable con-
ditions may occur.
MIN
DAY
SEC
Address
A2~A0
000
001
010
011
100
101
110
111
HT1380/HT1381
R/W
Bit
W
W
W
W
W
W
W
W
R
R
R
R
R
R
R
R
September 18, 2000
Command
10000000
10000001
10000010
10000011
10000100
10000101
10000110
10000111
10001000
10001001
10001010
10001011
10001100
10001101
10001110
10001111
Byte