PCA9624PW NXP Semiconductors, PCA9624PW Datasheet - Page 8

no-image

PCA9624PW

Manufacturer Part Number
PCA9624PW
Description
IC, LED DRIVER, RGBA, 24-TSSOP
Manufacturer
NXP Semiconductors
Datasheet

Specifications of PCA9624PW

No. Of Outputs
8
Output Current
100mA
Output Voltage
40V
Input Voltage
2.3V To 5.5V
Dimming Control Type
PWM
Driver Case Style
TSSOP
Switching Frequency
1MHz
Base Number
9624
Operating
RoHS Compliant
Led Driver Application
RGB Or RGBA LED Drivers, LED Status Information, Displays, Backlights
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PCA9624PW
Manufacturer:
PHILIPS
Quantity:
5 542
Part Number:
PCA9624PW
Manufacturer:
NXP
Quantity:
2 924
Part Number:
PCA9624PW
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
PCA9624PW
Quantity:
5 000
Part Number:
PCA9624PW,112
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
PCA9624PW,118
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
PCA9624PW118
Manufacturer:
NXP Semiconductors
Quantity:
135
Part Number:
PCA9624PWЈ¬112
Manufacturer:
NXP
Quantity:
551
NXP Semiconductors
PCA9624_2
Product data sheet
7.2 Control register
Following the successful acknowledgement of the slave address, LED All Call address or
LED Sub Call address, the bus master will send a byte to the PCA9624, which will be
stored in the Control register.
The lowest 5 bits are used as a pointer to determine which register will be accessed
(D[4:0]). The highest 3 bits are used as Auto-Increment flag and Auto-Increment options
(AI[2:0]).
When the Auto-Increment flag is set (AI2 = logic 1), the five low order bits of the Control
register are automatically incremented after a read or write. This allows the user to
program the registers sequentially. Four different types of Auto-Increment are possible,
depending on AI1 and AI0 values.
Table 3.
Remark: Other combinations not shown in
reserved and must not be used for proper device operation.
AI[2:0] = 000 is used when the same register must be accessed several times during a
single I
is overwritten each time the register is accessed during a write operation.
AI[2:0] = 100 is used when all the registers must be sequentially accessed, for example,
power-up programming.
AI[2:0] = 101 is used when the 16 LED drivers must be individually programmed with
different values during the same I
setting to another color setting.
AI2
0
1
1
1
1
Fig 6.
2
AI1
0
0
0
1
1
C-bus communication, for example, changes the brightness of a single LED. Data
reset state = 80h
Remark: The Control register does not apply to the Software Reset I
Control register
Auto-Increment options
AI0
0
0
1
0
1
Rev. 02 — 26 August 2009
Function
no Auto-Increment
Auto-Increment for all registers. D[4:0] roll over to 00h after the last
register (11h) is accessed.
Auto-Increment for individual brightness registers only. D[4:0] roll over to
02h after the last register (11h) is accessed.
Auto-Increment for global control registers only. D[4:0] roll over to 0Ah’
after the last register (0Bh) is accessed.
Auto-Increment for individual and global control registers only. D[4:0] roll
over to 02h after the last register (0Bh) is accessed.
AI2 AI1 AI0 D4
Auto-Increment flag
Auto-Increment options
2
C-bus communication, for example, changing color
Table 3
8-bit Fm+ I
register address
D3
D2
(AI[2:0] = 001, 010, and 011) are
D1
002aac147
2
C-bus 100 mA 40 V LED driver
D0
2
C-bus address.
PCA9624
© NXP B.V. 2009. All rights reserved.
8 of 37

Related parts for PCA9624PW