ADE7762ARWZ Analog Devices Inc, ADE7762ARWZ Datasheet - Page 14

no-image

ADE7762ARWZ

Manufacturer Part Number
ADE7762ARWZ
Description
IC, POLYPHASE ENERGY METERING, SOIC-28
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADE7762ARWZ

Ic Function
Polyphase Energy Metering IC With Phase Drop Indication
Supply Voltage Range
4.75V To 5.25V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
SOIC
No. Of Pins
28
Input Impedance
140 KOhm
Measurement Error
0.1%
Voltage - I/o High
2.4V
Voltage - I/o Low
0.8V
Current - Supply
8.5mA
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
28-SOIC (0.300", 7.50mm Width)
Meter Type
3 Phase
Brief Features
On-Chip Creep Protection, High Frequency Output
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-ADE7762EBZ - BOARD EVALUATION FOR ADE7762
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADE7762ARWZ
Manufacturer:
IXYS
Quantity:
1 120
ADE7762
ANALOG INPUTS
CURRENT CHANNELS
The voltage outputs from the current transducers are connected
to the ADE7762 current channels, which are fully differential
voltage inputs. IAP, IBP, and ICP are the positive inputs for IAN,
IBN, and ICN, respectively.
The maximum peak differential signal on the current channel
should be less than ±500 mV (353 mV rms for a pure sinusoidal
signal) for the specified operation.
The maximum signal levels on IAP and IAN are shown in
Figure 14. The maximum differential voltage between IAP
and IAN is ±500 mV. The differential voltage signal on the
inputs must be referenced to a common mode, for example,
AGND. The maximum common-mode signal shown in
Figure 14 is ±25 mV.
+500mV
–500mV
V
CM
IAP–IAN
Figure 14. Maximum Signal Levels, Current Channel
DIFFERENTIAL INPUT
±500mV MAX PEAK
COMMON-MODE
±25mV MAX
AGND
IA
V
CM
IAP
IAN
Rev. 0 | Page 14 of 28
VOLTAGE CHANNELS
The output of the line voltage transducer is connected to the
voltage inputs of the ADE7762. Voltage channels are pseudo-
differential voltage inputs. VAP, VBP, and VCP are the positive
inputs with respect to VN.
The maximum peak differential signal on the voltage channel is
±500 mV (353 mV rms for a pure sinusoidal signal) for a speci-
fied operation.
Figure 15 illustrates the maximum signal levels that can be
connected to the ADE7762 voltage channels.
Voltage channels must be driven from a common-mode voltage,
that is, the differential voltage signal on the input must be refer-
enced to a common mode (usually AGND). The analog inputs
of the ADE7762 can be driven with common-mode voltages of
up to 25 mV with respect to AGND. However, best results are
achieved using a common mode equal to AGND.
+500mV
–500mV
V
CM
VAP–VN
Figure 15. Maximum Signal Levels, Voltage Channel
DIFFERENTIAL INPUT
±500mV MAX PEAK
COMMON-MODE
±25mV MAX
AGND
VA
VCM
VAP
VN

Related parts for ADE7762ARWZ