ADE7762ARWZ Analog Devices Inc, ADE7762ARWZ Datasheet - Page 9

no-image

ADE7762ARWZ

Manufacturer Part Number
ADE7762ARWZ
Description
IC, POLYPHASE ENERGY METERING, SOIC-28
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADE7762ARWZ

Ic Function
Polyphase Energy Metering IC With Phase Drop Indication
Supply Voltage Range
4.75V To 5.25V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
SOIC
No. Of Pins
28
Input Impedance
140 KOhm
Measurement Error
0.1%
Voltage - I/o High
2.4V
Voltage - I/o Low
0.8V
Current - Supply
8.5mA
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
28-SOIC (0.300", 7.50mm Width)
Meter Type
3 Phase
Brief Features
On-Chip Creep Protection, High Frequency Output
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-ADE7762EBZ - BOARD EVALUATION FOR ADE7762
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADE7762ARWZ
Manufacturer:
IXYS
Quantity:
1 120
TYPICAL PERFORMANCE CHARACTERISTICS
–0.1
–0.2
–0.3
–0.4
–0.5
–0.2
–0.4
–0.5
–0.8
–1.0
–0.2
–0.4
0.5
0.4
0.3
0.2
0.1
1.0
0.8
0.6
0.4
0.2
1.0
0.8
0.6
0.4
0.2
Figure 6. Error As a Percent of Reading over Power Factor
Figure 7. Error As a Percent of Reading over Temperature
0
0
0
0.1
0.1
0.1
with Internal Reference (Wye Connection)
with Internal Reference (Wye Connection)
with Internal Reference (Wye Connection)
Figure 5. Error As a Percent of Reading
PHASE C
PHASE A + B + C
PHASE B
CURRENT CHANNEL (% of Full Scale)
CURRENT CHANNEL (% of Full Scale)
CURRENT CHANNEL (% of Full Scale)
–40°C, POWER FACTOR = 0.5
PHASE A
–40°C, POWER FACTOR = 1
+25°C, POWER FACTOR = 1
+85°C, POWER FACTOR = 1
1
1
1
+25°C, POWER FACTOR = 0.5
+25°C, POWER FACTOR = 1
+85°C, POWER FACTOR = 0.5
10
10
10
100
100
100
Rev. 0 | Page 9 of 28
–0.1
–0.2
–0.3
–0.4
–0.5
–0.5
–1.0
–1.5
–0.1
–0.2
–0.3
–0.4
–0.5
Figure 10. Error As a Percent of Reading over Power Supply
0.5
0.4
0.3
0.2
0.1
1.0
0.5
0.5
0.4
0.3
0.2
0.1
Figure 8. Error As a Percent of Reading over Temperature
0
0
0
Figure 9. Error As a Percent of Reading over Frequency
0.1
0.1
45
–40°C, POWER FACTOR = 1
with an Internal Reference (Wye Connection)
+25°C, POWER FACTOR = 1
with External Reference (Wye Connection)
with Internal Reference (Wye Connection)
POWER FACTOR = 0.5
5V
POWER FACTOR = 1
CURRENT CHANNEL (% of Full Scale)
CURRENT CHANNEL (% of Full Scale)
5.25V
50
LINE FREQUENCY (Hz)
1
1
4.75V
+85°C, POWER FACTOR = 1
55
10
10
60
ADE7762
100
100
65

Related parts for ADE7762ARWZ