ST62T08CB6 STMicroelectronics, ST62T08CB6 Datasheet - Page 13

no-image

ST62T08CB6

Manufacturer Part Number
ST62T08CB6
Description
IC, 8BIT MCU OTP 1K, 62T08, DIP20
Manufacturer
STMicroelectronics
Datasheet

Specifications of ST62T08CB6

Controller Family/series
ST6
Core Size
8bit
No. Of I/o's
12
Program Memory Size
1KB
Ram Memory Size
64Byte
Cpu Speed
8MHz
Oscillator Type
External Only
No. Of Timers
1
Digital Ic Case
RoHS Compliant
Peripherals
ADC, LVD
Rohs Compliant
Yes
Processor Series
ST62T0x
Core
ST6
Data Bus Width
8 bit
Program Memory Type
EPROM
Data Ram Size
64 B
Maximum Clock Frequency
8 MHz
Number Of Programmable I/os
12
Number Of Timers
2
Operating Supply Voltage
3 V to 6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
Package / Case
PDIP-20
Minimum Operating Temperature
- 40 C
On-chip Adc
8 bit
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST62T08CB6
Manufacturer:
TOSH
Quantity:
5 602
MEMORY MAP (Cont’d)
3.1.6 Data ROM Window
The Data read-only memory window is located
from address 0040h to address 007Fh in Data
space. It allows direct reading of 64 consecutive
bytes located anywhere in program memory, be-
tween address 0000h and 0FFFh.
There are 64 blocks of 64 bytes in a 4K device:
– Block 0 is related to the address range 0000h to
– Block 1 is related to the address range 0040h to
and so on...
All the program memory can therefore be used to
store either instructions or read-only data. The
Data ROM window can be moved in steps of 64
bytes along the program memory by writing the
appropriate code in the Data ROM Window Regis-
ter (DRWR).
Figure 5. Data ROM Window
0FFFh
0000h
003Fh.
007Fh.
PROGRAM
SPACE
64-BYTE
ROM
0FFh
07Fh
000h
040h
DATA SPACE
DATA ROM
WINDOW
3.1.6.1 Data ROM Window Register (DRWR)
The DRWR can be addressed like any RAM loca-
tion in the Data Space.
This register is used to select the 64-byte block of
program memory to be read in the Data ROM win-
dow (from address 40h to address 7Fh in Data
space). The DRWR register is not cleared on re-
set, therefore it must be written to before access-
ing the Data read-only memory window area for
the first time.
Address: 0C9h — Write Only
Reset Value = xxh (undefined)
Bits 7:6 = Reserved, must be cleared.
Bit 5:0 = DRWR[5:0] Data read-only memory Win-
dow Register Bits. These are the Data read-only
memory Window bits that correspond to the upper
bits of the data read-only memory space.
Caution: This register is undefined on reset, it is
write-only, therefore do not read it nor access it us-
ing Read-Modify-Write instructions (SET, RES,
INC and DEC).
7
-
ST6208C/ST6209C/ST6210C/ST6220C
-
DRWR5 DRWR4 DRWR3 DRWR2 DRWR1 DRWR0
13/104