Specifications of APDS-9006-020

Peak Wavelength
500 nm
Maximum Light Current
52 uA
Maximum Dark Current
300 nA
Maximum Rise Time
5 ms
Maximum Fall Time
5 ms
Package / Case
Chip LED-4
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Product
Ambient Light Sensor
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
516-1718-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
APDS-9006-020
Manufacturer:
AVAGO
Quantity:
20 000
Recommended Reflow Profile
The reflow profile is a straight-line representation of
a nominal temperature profile for a convective reflow
solder process. The temperature profile is divided into
four process zones, each with different DT/Dtime tem-
perature change rates or duration. The DT/Dtime rates or
duration are detailed in the above table. The tempera-
tures are measured at the component to printed circuit
board connections.
In process zone P1, the PC board and APDS-9006 pins
are heated to a temperature of 150°C to activate the flux
in the solder paste. The temperature ramp up rate, R1,
is limited to 3°C per second to allow for even heating of
both the PC board and APDS-9006 pins.
Process zone P2 should be of sufficient time duration (60
to 120 seconds) to dry the solder paste. The temperature
is raised to a level just below the liquidus point of the
solder, usually 200°C (392°F).
Process zone P3 is the solder reflow zone. In zone P3,
the temperature is quickly raised above the liquidus
point of solder to 255°C (491°F) for optimum results. The
9
150
120
255
230
217
200
180
25
80
Process Zone
Heat Up
Solder Paste Dry
Solder Reflow
Cool Down
Time maintained above °C
Peak Temperature
Time within 5°C of actual Peak Temperature
Time 5°C to Peak Temperature
0
HEAT
R1
P1
UP
50
SOLDER PASTE DRY
R2
Symbol
P, R
P, R
P3, R3
P3, R4
P4, R5
P2
100
DT
5°C to 50°C
50°C to 00°C
00°C to 55°C
55°C to 00°C
00°C to 5°C
> °C
60°C
> 55°C
5°C to 60°C
150
R3
60 sec to 90 sec
dwell time above the liquidus point of solder should be
between 20 and 40 seconds. It usually takes about 20
seconds to assure proper coalescing of the solder balls
into liquid solder and the formation of good solder con-
nections. Beyond a dwell time of 40 seconds, the inter-
metallic growth within the solder connections becomes
excessive, resulting in the formation of weak and un-
reliable connections. The temperature is then rapidly
reduced to a point below the solidus temperature of the
solder, usually 200°C (392°F), to allow the solder within
the connections to freeze solid.
Process zone P4 is the cool down after solder freeze.
The cool down rate, R5, from the liquidus point of the
solder to 25°C (77°F) should not exceed 6°C per second
maximum. This limitation is necessary to allow the PC
board and APDS-9006 pins to change dimensions evenly,
putting minimal stresses on the APDS-9006.
It is recommended to perform reflow soldering no more
than twice.
Above 217 C
MAX 260C
REFLOW
SOLDER
P3
200
R4
Maximum DT/Dtime
or Duration
3°C/s
00s to 80s
3°C/s
-6°C/s
-6°C/s
60s to 90s
0s to 40s
8mins
COOL DOWN
P4
R5
250
t-TIME
(SECONDS)
300

Related parts for APDS-9006-020