LC1D18P7 SQUARE D, LC1D18P7 Datasheet - Page 182

no-image

LC1D18P7

Manufacturer Part Number
LC1D18P7
Description
IEC Contactor
Manufacturer
SQUARE D
Datasheet

Specifications of LC1D18P7

No. Of Poles
3
Contact Configuration
3PST-NO
Relay Mounting
DIN Rail
Width
45mm
Relay Terminals
Screw Clamp
Operating Voltage
600VAC
Switching Power Ac1
3hp
Switching Power Ac3
15hp
Switching Current Ac1
32A
Switching Current Ac3
18A
Load Current Inductive
18A
Load Current Resistive
32A
Characteristics
182
Type
Environment
Rated insulation voltage (Vi)
Rated impulse withstand voltage (Vimp)
Conforming to standards
Approvals
Degree of protection
Protective treatment
Ambient air temperature
around the device
Maximum operating altitude
Operating positions
Shock resistance c
1/2 sine wave = 11 ms
Vibration resistance c
5 to 300 Hz
Pole Characteristics
Number of poles
Rated operational current (Ie)
(Ve
Rated operational voltage (Ve)
Frequency limits
Conventional rated thermal current
Rated making capacity
Rated breaking capacity
Permissible short time rating from cold
state, no current flowing for preceding 60
minutes
Short-circuit protection
Average impedance per pole
Power dissipation per pole for the above
operational currents
Mechanical durability at nominal voltage Millions of operations
Maximum operating rate
Cabling
Tightening torque using
DZ2F
f
c
q
p
40 °C (104 °F)
In these conditions, for ratings F115 to F225, it is recommended to use LX9F coils.
In the least favorable direction, without change of contact state (coil at Vc).
Paralleling of poles must be carried out only in accordance with the fuse manufacturer's recommendations.
Sine wave without interference, above these values, please consult your Local Square D Field Sales Office.
440 V)
©
Lug
2001-2004 Schneider Electric All Rights Reserved
q
Characteristics
Contactors Type LC1F (115 to 800A)
Control Circuit: AC or DC Supply
Conforming to
IEC 60947-4-1/IEC 60947-4
Conforming to VDE 0110 gr C
Test with coil not
connected to the power circuit
Conforming to IEC 60529
Conforming to VDE 0106
Standard version
Storage
Operation
Permissible at Vc f
Without derating
Without derating
Contactor open
Contactor closed
Contactor open
Contactor closed
In AC-3, q
In AC-1, q
Up to
Of the operational current p
I rms to IEC 60947-4-1
I rms
conforming to
IEC 60947-4-1
For 1 s
For 5 s
For 10 s
For 30 s
For 1 min
For 3 min
For 10 min
By circuit breaker
By fuses
At Ith and 50 Hz
AC-3
AC-1
Cable size (min-max)
Lug
Bolt lug to contactor
Wire pressure screw
55°C (131°F)
40 °C (104 °F)
E164862
NLDX
Meets the essential
requirements of the LV &
EMC directives
55 °C (131 °F)
40 °C (104 °F)
up to 440 V
500 V
660 to 690 V
1000 V
LR 43364
3211 04
V
V
kV
A
A
V
Hz
A
A
A
A
A
A
A
A
A
A
A
A
A
m
W
W
ops/HR 2400
AWG
lb.-in
lb.-in
LC1F115
1000
1500
8
IEC 60947-4, NFC 63-110, VDE 0660, BS 5424, JEM 1038
ASE, CSA, UL, BV, GL, LROS, USSR, NORSK VERITAS, RINA
IP 20 front face with shrouds LA9F
Protection against direct finger contact with shrouds LA9F
“TH”
- 60 to + 80 °C (- 76 to +176 °F)
- 5 to + 55 °C (23 to + 131 °F) for operation at 80 to 110% of nominal control voltage
- 40 to + 70 °C (- 40 to + 158 °F) for operation at nominal control voltage
3000 m (9800 ft.)
± 30° possible, in relation to normal vertical mounting plane
9 gn
13 gn
2 gn
6 gn
3 or 4
115
200
1000
16
200
1400
1300
1100
900
400
1100
1100
1100
640
520
400
320
Select in accordance with NEC and local codes
Max 400% of motor FLA
0.40
6
18
10
#14 to 2/0
DZ2FF
89
120
2/3
to 200
LC1F150
1000
1500
8
9 gn
13 gn
2 gn
6 gn
3 or 4
150
250
1000
16
250
1700
1500
1200
1100
450
1200
1200
1200
700
600
450
350
0.40
9
25
10
2400
#6 to 3/0
DZ2FG
160
200
2/3
to 200
LC1F185
1000
1500
8
7 gn
15 gn
2 gn
5 gn
3 or 4
185
275
1000
16
275
2100
1800
1600
1200
600
1500
1500
1500
920
740
500
400
0.36
12
26
10
2400
#6 to 3/0
DZ2FG
160
200
2/3
to 200
LC1F225
1000
1500
8
7 gn
15 gn
2 gn
5 gn
3 or 4
225
315
1000
16
315
2460
2050
1850
1350
780
1800
1800
1800
1000
850
560
440
0.36
18
10
2400
35
2/3
to 200
LC1F265
1000
1500
8
6 gn
15 gn
2 gn
5 gn
3 or 4
265
350
1000
16
350
2940
2450
2200
1700
800
2200
2200
2200
1230
950
620
480
0.32
22
39
10
2400
#6 to 300mcm
DZ2FH
310
275
2/3
to 200
01/04