LC1D18P7 SQUARE D, LC1D18P7 Datasheet - Page 220

no-image

LC1D18P7

Manufacturer Part Number
LC1D18P7
Description
IEC Contactor
Manufacturer
SQUARE D
Datasheet

Specifications of LC1D18P7

No. Of Poles
3
Contact Configuration
3PST-NO
Relay Mounting
DIN Rail
Width
45mm
Relay Terminals
Screw Clamp
Operating Voltage
600VAC
Switching Power Ac1
3hp
Switching Power Ac3
15hp
Switching Current Ac1
32A
Switching Current Ac3
18A
Load Current Inductive
18A
Load Current Resistive
32A
LR9F Solid State Overload Relays - Selection
LR9F53
LR9F73
DZ2F
LR9F73
220
©
2001-2004 Schneider Electric All Rights Reserved
LR9F Solid State Overload Relays - Selection
Three-Phase Overload Relays
Lug Kits
Lugs can be ordered either individually or in sets of six. In some cases the LR9F overload relay mounted
directly on the bottom of LC1F contactor will require a different size lug than the contactor itself. Refer
to the table below to select the appropriate size lug for your choice of contactor and overload. If all 6 lugs
(three for line side of contactor, three for load side of overload relay) are the same, Square D offers a
pre-packaged set of six lugs. If the two sizes are different, order 3 of each size lug. Mounting hardware
(screws, washers, nuts) are provided with the contactors and overload relays, not with the lugs.
a
Insulated Terminal Blocks
For contactors LC1F115, LC1F150, and LC1F185, an available touch-safe terminal block may be used
in place of lugs for power connections
Current Setting Range
Amps
30 to 50
48 to 80
60 to 100
90 to 150
132 to 220
200 to 330
300 to 500
380 to 630
c
q
f
Overload Relay
LR9F5 57 to F5 69
LR9F5 57 to F5 71
LR9F5 71
LR9F7 75 to F7 79
LR9F7 75 to F7 81
LR9F7 75 to F7 81
LR9F7 81
Insulated terminal block
LA9F103
Customer to obtain from local supplier.
When mounting overload relays LR9F5 57 to LR9F5 71 directly beneath the contactor it is recommended that the relays be additionally supported
by a mounting plate. For sizes LR9F5 75 to LR9F7 81 use of the supporting mounting plate is mandatory. See page 221 for selection table.
IEC standard 60947-4 specifies the following trip times when the overload relay senses 7.2 times the setting current:
Class 10: between 4 and 10 seconds
Class 20: between 6 and 20 seconds
Interconnection kit LA7F407 is required to mount an LR9F 71 to an LCIF185.
Directly mounted to
contactor LC1
F115
F150 or F185
F265
F265 or F330
F400
F500
F630
For Direct Mounting To Contactor
LC1
F115 to F185
F115 to F185
F115 to F185
F115 to F185
F185 f, F265
F265 to F500
F265 to F500
F400 to F630
Cable size
AWG range
#6 to 300 MCM
/CR1F
c
Cable size AWG range
Line side (of contactor) Load side (of overload)
14 to 2/0
6 to 3/0
6 to 300 MCM
6 to 300 MCM
4 to 500 MCM
2 x 2 to 600 MCM
3 x 2 to 600 MCM
6 to 3/0
4 to 500 MCM
4 to 500 MCM
4 to 500 MCM
4 to 500 MCM
Class 10 Trip q
Catalog Number
LR9F5357
LR9F5363
LR9F5367
LR9F5369
LR9F5371
LR9F7375
LR9F7379
LR9F7381
Suitable for contactor
LC1
F115, F150, F185
/CR1
Lug Catalog Number
Line side (of
contactor)
3 ea. DZ2FF1
1 ea. DZ2FG6
1 ea. DZ2FH6
3 ea. DZ2FH1
3 ea. DZ2FJ1
3 ea. DZ2FK1
DZ2FL1
DZ2FL2
DZ2FL3
Class 20 Trip q
Catalog Number
LR9F5557
LR9F5563
LR9F5567
LR9F5569
LR9F5571
LR9F7575
LR9F7579
LR9F7581
Suitable for overload relay
LR9
5 57, F5 63, F5 67, F5 69
Load side (of
overload)
3 ea. DZ2FG1
a
a
a
a
08/04