M18TUP6E BANNER ENGINEERING, M18TUP6E Datasheet - Page 2

Infrared Temperature Sensor

M18TUP6E

Manufacturer Part Number
M18TUP6E
Description
Infrared Temperature Sensor
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of M18TUP6E

Field Of View
6
Operating Temperature Range
-20°C To +70°C
Response Time
75ms
Sensing Face Type
Enclosed Plastic
Wavelength Typ
14µm
Rise Time
75ms
Opto Case Style
Module
Sensor Output
Voltage
Features
Enclosed Plastic Face
The T-GAGE analog sensor is a passive, non-contacting, temperature-based device. It is
used to detect object(s) temperature within a sensing window and output a proportional
voltage.
While it looks and operates just like an Expert™ photoelectric sensor, the T-GAGE detects
the infrared light energy emitted by objects, instead of its own emitted light. The sensor
uses a thermopile detector, made up of multiple infrared-sensitive elements (thermocouples)
to detect this infrared energy within its field of view (see Figure 2).
Potential applications include:
• Hot part detection (baked goods, metals, bottles, rubber)
• Ejection verification of injection-molded parts
• Flame process verification
• Hot glue detection (packaging equipment, book binding, product assembly)
• Cold part detection (frozen foods, ice, dairy)
• Roller monitoring
NOTE: The T-GAGE M18T sensor is not intended for absolute temperature measurement
Sensing Field of View
The sensing range is determined by the sensor’s field of view (FOV), or viewing angle,
combined with the size of the object(s) being detected (see Figure 2). The sensor’s distance-
to-spot size ratio (D:S ratio) is inversely related to the viewing angle; a sensor with a small
viewing angle will have a large D:S ratio. The T-GAGE M18T sensors have D:S ratios of 6:1,
8:1 or 14:1. For a sensor with an 8:1 D:S ratio, the sensor’s spot size is a 1" diameter circle
at a distance of 8"; farther from the sensor face the spot size will be larger.
Figure . Detection spot size versus distance from sensor
T-GAGE
     
D:S Ratio
Sensor
P/N 123698
14:1
6:1
8:1
or for safety-related fire detection use.
Distance (mm)
100
17
13
7
M18T Series Temperature Sensors –
00
33
25
14
300
50
38
21
200
400
67
50
29
Distance From Sensor Face Versus Spot Size
500
83
63
36
Overview
400
600
100
75
43
700
117
88
50
600
800
133
100
57
900
150
113
64
800
1000
167
125
71
Distance (mm)
Spot Size
(mm)
1000
(see table)
Spot Size
Analog Output
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
Figure 1. Sensor features
Power/Teach
LED
PWR
TEACH
OUT
Minneapolis, MN U.S.A.
TEACH
Push Button
Alarm Output
LED

Related parts for M18TUP6E