C500-AP003 Omron, C500-AP003 Datasheet - Page 74

no-image

C500-AP003

Manufacturer Part Number
C500-AP003
Description
PROGRAMMING CONSOLE ADAPTER
Manufacturer
Omron
Datasheets

Specifications of C500-AP003

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Safety Considerations
Output Surge Current
Transistor Output Residual
Voltage
Determine the value and rating for the bleeder resistor using the following for-
mula.
Where
E
I = leakage current in mA
R = bleeder resistance
When connecting a transistor or triac Output Unit to an output device having a
high surge current (such as an incandescent lamp), care must be taken to avoid
damage to the Output Unit. The transistor and triac Output Units are capable of
withstanding a surge current of ten times the rated current. If the surge current
for a particular device exceeds this amount, use the circuit shown below to pro-
tect the Output Unit.
Another way of protecting the Output Unit lets the load draw a small current
(about one third the rated current) while the output is OFF, significantly reducing
the surge current. This circuit (shown below) not only reduces the surge current,
but also reduces the voltage across the load at the same time.
When connecting TTL circuits to transistor Output Units, connect a pull-up resis-
tor and a CMOS IC between the two. This is because of the residual voltage left
on the transistor output after the output turns OFF.
R
COM
COM
OUT
OUT
on
= ON voltage of the load
E
ON
I
R
R
L
L
+
+
Section 7
61

Related parts for C500-AP003