CQM1H-series PLCs
SEND
178
Introduction
@SEND(90)
D
C
S
S: Source node beginning send word
D: Destination node beginning receive word
C: Source node first control data word
C +1 1
C + 2
C + 3
C
15 14
1514131211
15
Destination unit address
00 (Hex):
01 to 0F (Hex):
FE (Hex):
15
Destination network address
00 (Hex):
01 to 7F (Hex):
This setting is enabled only when Destination network address specified" is set in word C.
When specifying a destination network address, set all the nodes in the routing tables. For de
tails on routing tables, refer to
Note
0: Destination network address not specified (local network)
1: Destination network address specified.
10 to 1F (Hex):
1
Always "1" for Controller Link Networks
Always "1" for Controller
Link Networks
0: Response required
1: Response not required
"n" number of send words
0000 to 03DE (Hex): 0 to 990 words
Direct/Indirect
0: Direct; 1: Indirect
Number of retries
0 to F (Hex): 0 to 15 retries
SEND transmits “n” words beginning with S (the beginning word for data
transmission at the source node) to “n” words beginning with D (the beginning
word for data reception at the destination node, N.)
1. When communicating in the same network with CVM1 and CV-series
2. With the message service, there is no guarantee that a message to a des-
8 7
8 7
PLCs manufactured prior to April 1996, the local network address cannot
be set to “00.” Set a number other than “00” as the local network address
in the routing tables, and then specify that number.
tination node will reach its destination. It is always possible that the mes-
sage may be lost in transit due to noise or some other condition. When
using the message service, it is advisable to prevent this situation from oc-
curring by performing resend processing at the node where instructions
are executed. With the SEND, RECV, and CMND instructions, resend pro-
cessing is performed automatically once the number of retries has been
set, so be sure to specify a number other than “0” for the number of retries.
0
PLC's CPU Unit
Computer (user program)
(02 to 0F (Hex) are used
when using Controller Link
Support Boards for PCI
Bus only.)
Unit Nos. 0 to 15
Unit connected to network
Local network
1 to 127
0
0
0
0
0
Section 7 Network Interconnections.
Response monitor time
00 (Hex):
FF (Hex):
01 to FE (Hex):
S
Destination node address (N)
01 to 20 (Hex): 1 to 32 (or 01 to 3E (Hex): 1 to 62)
The same data can be broadcast to all nodes
on the network by setting the destination node
address to FF (Hex).
The range of node addresses will vary for networks
other than Controller Link Networks.
15
Source node
0.1 to 25.4 s (unit: 0.1 s)
2 s (for 2 Mbps)
4 s (for 1 Mbps)
8 s (for 500 Kbps)
No response monitoring
0
"n" number
of send
words
n
D
Destination node N
15
Section 6-1
0
n