NT600SST211BEV3 Omron, NT600SST211BEV3 Datasheet - Page 483

no-image

NT600SST211BEV3

Manufacturer Part Number
NT600SST211BEV3
Description
Controllers, Display
Manufacturer
Omron
Datasheet

Specifications of NT600SST211BEV3

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Lead free / RoHS Compliant
Data Conversion
Correction related to extended I/O input/output table
Correction of image codes
S Difference
S Conversion result, error message and corrective action
When an extended I/O input/output table is converted, the data is converted in
the manner shown below due to differences in the handling of an extended I/O
input/output table between NT30/NT30C and other models.
S Difference
S Conversion result, error message and corrective action
When an image code is converted between a conventional and a new model,
conversion is executed in the manner shown below due to differences in the
image codes between them.
S Difference
New models:
Conventional models:
NT30/NT30C:
Other models:
New models:
Conventional models:
[Switch screen]: OFF
[Screen No]: 0
[Switch screen]: OFF
[Screen No]: As desired
[Switch screen]: OFF
[Screen No]: 0
[Switch screen]: ON
[Screen No]: As desired
With an NT30/
NT30C, an ex-
tended I/O input/
output table is set.
Status before
Conversion
Status before
Conversion
With a PT model
other than NT30/
NT30C, the setting
of an extended I/O
input/output table is
discarded.
Function: None
[Switch screen]: OFF
[Screen No]: 0
Function: Alarm
[Switch screen]: ON
[Screen No]: As desired
Function: Alarm
[Switch screen]: ON
[Screen No]: 9999
Function: Alarm
[Switch screen]: ON
[Screen No]: As desired
Status after
Conversion
Alarm function and switch screen function cannot be
set simultaneously.
Alarm function and switch screen function can be set
simultaneously.
Extended I/O input/output table can be used.
Extended I/O input/output table cannot be used.
0001 to 0FFF (hexadecimal)
FE20 to FEFF (hexadecimal)
Status after
Conversion
Error Message
Message
––
Error
––
––
––
––
Change function to
[Alarm], if you want to dis-
play the alarm. (Refer to
7-4 Bit Memory Table.)
Correction is not neces-
sary.
Correction is not neces-
sary.
Change the function to
[Switch screen]. (Refer to
7-4 Bit Memory Table.)
Correct the screen data
and a host program so
that unusable table
entries can be replaced
with inputs/outputs of a
host, etc. (Refer to 7-5
Extended I/O Input
Table and 7-6 Extended
I/O Output Table.)
Corrective Action
Corrective Action
Appendix A
471