D4NL-1AFA-B Omron, D4NL-1AFA-B Datasheet - Page 5

SAFETY SWITCH

D4NL-1AFA-B

Manufacturer Part Number
D4NL-1AFA-B
Description
SAFETY SWITCH
Manufacturer
Omron
Datasheets

Specifications of D4NL-1AFA-B

Contact Voltage Ac Max
240V
Contact Voltage Dc Max
24V
Contact Current Ac Max
10A
Contact Current Dc Max
200mA
Switch Terminals
Screw
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
EN60747-5-1, IEC 947-5-1, EN1088,
Contact Configuration
SPST-NC / SPST-NO
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Note: 1. The above values are initial values.
Degree of protection (see note 2)
Durability
(see note 3)
Operating speed
Operating frequency
Rated frequency
Contact gap
Direct opening force (see note 5)
Direct opening travel (see note 5)
Holding force (see note 6)
Insulation resistance
Minimum applicable load (see note 7)
Rated insulation voltage (U
Rated open thermal current (I
Impulse withstand voltage (EN60947-5-1)
Conditional short-circuit current
Pollution degree (operating environment)
Protection against electric shock
Contact resistance
Vibration resis-
tance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Characteristics
2. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are suffi-
3. The durability is for an ambient temperature of 5 ° C to 35 ° C and an ambient humidity of 40% to 70%. For more details, consult your OM-
4. If the ambient temperature is greater than 35 ° C, do not pass the 3-A, 250-VAC load through more than 2 circuits.
5. These figures are minimum requirements for safe operation.
6. This figure is based on the GS-ET-19 evaluation method.
7. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the ac-
cient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do
not use the D4NL in places where foreign material may penetrate through the key hole on the head, otherwise Switch damage or mal-
functioning may occur.
RON representative.
tual load beforehand.
Mechanical
Electrical
Malfunction
Destruction
Malfunction
i
)
th
)
IP67 (EN60947-5-1)
(This applies for the Switch only. The degree of protection for the key hole is IP00.)
1,000,000 operations min.
500,000 operations min. for a resistive load of 3 A at 250 VAC (see note 4)
0.05 to 0.5 m/s
30 operations/minute max.
50/60 Hz
2 x 2 mm min
60 N min. (EN60947-5-1)
10 mm min. (EN60947-5-1)
1,300 N min.
100 M W min. (at 500 VDC)
Resistive load of 1 mA at 5 VDC (N-level reference value)
300 V (EN60947-5-1)
10 A (EN60947-5-1)
Between terminals of the same polarity
Between terminals of different polarities
Between other terminals and uncharged metallic parts
100 A (EN60947-5-1)
3 (EN60947-5-1)
Class II (double insulation)
25 m W max. per contact (initial value)
10 to 55 Hz, 0.75-mm single amplitude
1,000 m/s
300 m/s
Operating: - 10 ° C to 55 ° C with no icing
Operating:95% max.
Approx. 370 g (D4NL-IAFA-B)
2
min. (100 m/s
2
min.
2
min. for the lock monitor switch)
Guard Lock Safety-door Switch
2.5 kV
4 kV
6 kV
D4NL