MCBACIP CARLO GAVAZZI, MCBACIP Datasheet - Page 4

BACNET-IP PORT MODULE

MCBACIP

Manufacturer Part Number
MCBACIP
Description
BACNET-IP PORT MODULE
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of MCBACIP

Accessory Type
BACNet-IP Port Module
For Use With
WM3096 Type Smart Modular Power Analyzer
WM30 96
Output specifications
Relay outputs (M O R2)
Insulation
Static outputs (M O O2)
4
Physical outputs
Purpose
Type
Configuration
Function
Physical outputs
Purpose
Signal
Configuration
Function
Alarms
Alarms
Pulse
Min. response time
Signal retransmission
Pulse type
Pulse duration
Remote controlled
outputs
2 (max. one module per
instrument)
For either alarm output or
pulse output
Relay, SPDT type
AC 1-5A @ 250VAC; AC
15-1.5A @ 250VAC
DC 12-5A @ 24VDC; DC
13-1.5A @ 24VDC
By means of the front key-
pad
The outputs can work as
alarm outputs but also as
pulse outputs, remote
controlled outputs, or in
any other combination.
Up alarm and down alarm
linked to the virtual alarms,
other details see Virtual
alarms
≤200ms, filters excluded.
Set-point on-time delay: “0
s”.
Total: +kWh, -kWh, +kvarh,
-kvarh.
Partial: +kWh, -kWh,
+kvarh, -kvarh.
The above listed variables
can be connected to any
output.
Programmable from 0.001
to 10.00 kWh/kvarh per
pulse. ≥100ms <120msec
(ON), ≥120ms (OFF),
according to EN62052-31
The activation of the
outputs is managed
through the serial
communication port
See “Insulation between
inputs and outputs” table
Opto-Mos type
2 (max. one module per
instrument)
For either pulse output or
alarm output
V
V
By means of the front key-
pad
The outputs can work as
alarm outputs but also as
pulse outputs, remote
controlled outputs, or in
any other combination.
Up alarm and down alarm
linked to the virtual alarms,
other details see Virtual
alarms
ON
OFF
:2.5VAC/DC/max.100mA
: 260VAC/DC max.
Specifications are subject to change without notice
Insulation
20mA analogue outputs
(M O A2)
10VDC analogue outputs
(M O V2)
Pulse
Number of outputs
Accuracy
(@ 25°C ±5°C, R.H. ≤60%)
Range
Configuration
Signal retransmission
Scaling factor
Response time
Ripple
Total temperature drift
Load
Insulation
Number of outputs
Accuracy
(@ 25°C ±5°C, R.H. ≤60%)
Range
Configuration
Min. response time
Signal retransmission
Pulse type
Pulse duration
Remote controlled outputs
≤200ms, filters excluded.
Set-point on-time delay: “0
s”.
Total: +kWh, -kWh, +kvarh,
-kvarh.
Partial: +kWh, -kWh,
+kvarh, -kvarh.
The above listed variables
can be connected to any
output.
Programmable from 0.001
to 10.00 kWh/kvarh per
pulse.
≥100ms < 120msec (ON),
≥120ms (OFF), according
to EN62052-31
The activation of the
outputs is managed
through the serial
communication port
See “Insulation between
inputs and outputs” table
2 (max. one module per
instrument)
±0.2%FS
0 to 20mA
By means of the front key-
pad
The signal output can be
connected to any
instantaneous variable
available in the table “List
of the variables that can be
connected to”.
Programmable within the
whole range of
retransmission; it allows
the retransmission
management of all values
from 0 to 20 mADC.
≤400 ms typical (filter
excluded)
≤1% (according to IEC
60688-1, EN 60688-1)
≤500 ppm/°C
≤600Ω
See “Insulation between
inputs and outputs” table
2 (max. one module per
instrument)
±0.2%FS
0 to 10 VDC
By means of the front key-
pad
WM30 96 DS 271109