MCBACIP CARLO GAVAZZI, MCBACIP Datasheet - Page 8

BACNET-IP PORT MODULE

MCBACIP

Manufacturer Part Number
MCBACIP
Description
BACNET-IP PORT MODULE
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of MCBACIP

Accessory Type
BACNet-IP Port Module
For Use With
WM3096 Type Smart Modular Power Analyzer
WM30 96
Main functions (cont.)
Filter
Displaying
Virtual alarms
No. of alarms
Working mode
Hysteresis
8
General specifications
Operating temperature
Storage temperature
Installation category
Insulation (for 1 minute)
Operating range
Filtering coefficient
Filter action
Number of variables
Backlight
Working condition
Controlled variables
Set-point adjustment
Selectable from 0 to 100%
of the input display scale
Selectable from 1 to 32
Measurements, analogue
signal retransmission,
serial communication
(fundamental variables: V,
A, W and their derived
ones).
Up to 5 variables per page.
See “Front view”. 7
different set of variables
available (see “Display
pages”) according to the
application being selected.
One page is freely
programmable as
combination of variables.
The backlight time is
programmable from 0
(always on) to 255 minutes
In case of basic unit or
with the addition of M O
R2 or M O O2 digital
output modules.
Up to 4
Up alarm and down alarm.
The alarms can be
connected to any
instantaneous variable
available in the table “List
of the variables that can be
connected to”.
From 0 to 100% of the
display scale
From 0 to full scale
-25°C to +55°C (-13°F to
131°F) (R.H. from 0 to 90%
non-condensing @ 40°C)
according to EN62053-21,
EN50470-1 and EN62053-
23
158°F) (R.H. < 90% non-
condensing @ 40°C)
according to EN62053-21,
EN50470-1 and EN62053-
23
Cat. III (IEC60664,
EN60664)
See “Insulation between
inputs and outputs” table
-30°C to +70°C (-22°F to
Specifications are subject to change without notice
On-time delay
Min. response time
Reset
Harmonic analysis
Clock
Easy connection function
Dielectric strength
Noise rejection CMRR
EMC
Functions
Time format
Date format
Battery life
Electrostatic discharges
Immunity to irradiated
Electromagnetic fields
Burst
Immunity to conducted
disturbances
Surge
0 to 9999s
≤ 200ms, filters excluded.
Set-point on-time delay:
“0 s”.
By means of the front key-
pad. It is possible to reset
the following data:
- all the max and dmd
values.
- total energies: kWh,
kvarh;
- partial energies: kWh,
kvarh
Up to the 32
on current and voltage
Universal clock and calendar.
Hour: minutes: seconds
with selectable 24 hours or
AM/PM format.
Day-month-year with
selectable DD-MM-YY or
MM-DD-YY format.
10 years
For all the display
selections, both energy
and power measurements
are independent from the
current direction. The
displayed energy is always
“imported” with the only
exception of “D”, “F” and
“G” types (see “display
pages” table). For those
latter selections the
energies can be either
“imported” or “exported”
depending on the current
direction.
4kVAC RMS for 1 minute
100 dB, 48 to 62 Hz
According to EN62052-11
15kV air discharge
Test with current: 10V/m
from 80 to 2000MHz
Test without any current:
30V/m from 80 to 2000MHz
On current and voltage
measuring inputs circuit:
4kV
10V/m from 150KHz to
80MHz
On current and voltage
measuring inputs circuit:
4kV; on “L” auxiliary power
WM30 96 DS 271109
nd
harmonics

Related parts for MCBACIP