ELC-GP04-03 EATON CUTLER HAMMER, ELC-GP04-03 Datasheet - Page 53

Graphics Panel

ELC-GP04-03

Manufacturer Part Number
ELC-GP04-03
Description
Graphics Panel
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of ELC-GP04-03

No. Of Functions
10
Pixel Format
128 X 64
For Use With
ELC Logic Controllers
February 2007
QCPort Starter Network
Adapter Product (QSNAP)
Product Description
The Cutler-Hammer
Network Adapter Product (QSNAP)
from Eaton’s electrical business is a
front-mount device providing commu-
nication capability, control and moni-
toring to Intelligent Technologies (IT.)
Electromechanical Starters, as well as
the S751 and S752 Soft Start, as listed
in Tables 75 – 77.
The IT. QSNAP has an optional HANDS/
OFF/AUTO (HOA) module that enables
the starter to be operated in hand
mode; even if the QSNAP is not pow-
ered. The HOA option is used for cus-
tomers who need the extra security of
manual control in conjunction with
industrial network communication
capabilities.
Figure 69. Typical QSNAP Application
CA05001001K
To Control
PC or PLC
Catalogue Number D77B-QSNAP-
X1
D77D-DNA D77A I/O
®
QCPort Starter
IT. Starters with QSNAPs
For more information visit: www.EatonElectrical.ca
With the addition of a D64 zero
sequence CT, the QSNAP can be
enabled to detect ground faults for
added protection.
Features
Comprehensive Motor Data and
Control
Extended Starter Capabilities
QCPort connectivity connecting
motor control and I/O on same
network adapter
Configuration using a software
application is not required for nor-
mal operation
Advanced configuration using
CH Studio
Includes pre-wired starter intercon-
nect cable and terminal adapter
RMS average current
% of operating FLA
% thermal memory
Integral contact position detection
Operating status and fault codes
At speed (soft starters)
START/STOP control
RUN/FORWARD-REVERSE control
Trip Reset
Ground fault detection (with
accessory)
Fault log
Overcurrent warning (adjustable)
Undercurrent warning (adjustable)
Emergency stop detection
PLC, I/O & Communications Products
IT. Connect
Starter Network Adapters (SNAP) (D77B Series) — QCPort SNAP
QCPort
D77A I/O
24V DC IT.
Supply
Table 75. IEC SNAP Connectivity
Table 76. NEMA SNAP Connectivity
Table 77. S751/S752 SNAP Connectivity
Application Description
A typical application for the QSNAP
will contain many QSNAPs and many
I/O products all connected to a single
network adapter. With this architec-
ture, an entire panel can be repre-
sented by a single network adapter.
IEC E101, E501
Frame
105 mm
140 mm
NEMA N101, N501
Size
00
S751/S752 Soft Start
54 mm
45 mm
54 mm
76 mm
0
1
2
3
4
5
Size
B
C
D
E
F
All Sizes
Continuous Ampacity
Rating
135
270
18
27
45
90
9
Continuous
Ampacity
Rating
100 Amp
125 Amp
160 Amp
200 Amp
250 Amp
315 Amp
420 Amp
18 Amp
25 Amp
32 Amp
40 Amp
50 Amp
65 Amp
85 Amp
53