ELC-GP04-03 EATON CUTLER HAMMER, ELC-GP04-03 Datasheet - Page 59

Graphics Panel

ELC-GP04-03

Manufacturer Part Number
ELC-GP04-03
Description
Graphics Panel
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of ELC-GP04-03

No. Of Functions
10
Pixel Format
128 X 64
For Use With
ELC Logic Controllers
February 2007
Product Description
The Cutler-Hammer
nologies (IT.) EtherNet/IP (D77D-EIP)
from Eaton’s electrical business has
greatly increased the functionality of
Cutler-Hammer IT. communicating
products, allowing monitoring and
control for IT. I/O and IT. motor control
devices. The adapter concentrates all
data from these devices into a single
EtherNet/IP node.
The EtherNet/IP Adapter is a slave
device on EtherNet/IP and a master on
QCPort.
To simplify the configuration of the
D77D-EIP, a simple auto-configure
button press sets the system up for
default operation. This automatically
configures the EtherNet/IP assemblies
to the QCPort system devices
Application Description
In a typical EtherNet/IP Adapter appli-
cation, the D77D-EIP connects directly
to EtherNet/IP, and resides in a system
with IT. I/O and other communicating
motor controls. The data from these
IT. devices is assembled into input and
output assemblies before being pre-
sented to EtherNet/IP.
CA05001001K
Cat. No. D77D-EIP
®
Intelligent Tech-
For more information visit: www.EatonElectrical.ca
Features, Functions and Benefits
Standards and Certifications
Approvals
Table 89. Approvals/Certifications
Electrical/EMC
Other Approvals
Technical Data and Specifications
Table 90. Environmental Ratings
Transportation/Storage
Operating
Description
ESD Immunity (IEC 61000-4-2)
Radiated Immunity (IEC 61000-4-3)
Fast Transient (IEC 61000-4-4)
Surge (IEC 61000-4-5)
RF Conducted (IEC 61000-4-6)
Magnetic Field (IEC 61000-4-8)
Ingress Protection Code
Radiated and Conducted Emissions EN 5011 Class A
Agency Certifications
Description
Temperature
Humidity
Temperature
Humidity
Altitude
Shock
(IEC 68-2-27)
Vibration
(IEC 68-2-6)
Pollution Degree
Communication to EtherNet/IP
consuming one address
Supports Boot P, DHCP and static
IP addressing
10 BaseT Connection
Provides for control of all IT. com-
municating devices connected to
the network adapter
Single button press auto configures
the gateway, setting up the system
for default operation
Advanced configuration using
CH Studio
PLC, I/O & Communications Products
IT. Connect
Communication Adapters (D77D Series) — EtherNet/IP Adapter
consult factory
15G any direction for
11 mS
5 – 150 Hz, 5G .7 mm
maximum peak-to-peak
Specification
-58° – 176°F (-50° – 80°C)
5 – 95% non-condensing
-13° –149 °F (-25° – 65°C)
5 – 95% non-condensing
Above 6,600 ft. (2,000m)
2
Specification
± 8 kV air, ± 4 kV contact
10V/m 80 – 1,000 MHz, 80% amplitude modulation @ 1 kHz
± 2 kV supply and control, ± 1 kV communications
± 1 kV line-to-ground, ± 2 kV line-to-line
10V, .15 – 80 MHz
30A/m, 50 Hz
IP20
UL 508, CUL (CSA C22.2 No. 14), CE (Low Voltage Directive),
Modbus Conformance Tested
Table 91. EtherNet/IP Specifications
Description
Connections
I/O Size
Baud
Addressing
QCPort Channels 2 Independent
Provides for backplane and inter-
connect cable connections to
QCPort
Two independent QCPort (commu-
nication) ports
Powered from QCPort
Isolated from EtherNet/IP
Status LEDs for EtherNet/IP, QCPort
and module health
Provides for configuration of QCPort
devices over EtherNet/IP
Small package size
DIN rail mountable
504 bytes Output
Ethernet 10 Megabit
or DHCP
Channels
Specification
10 BaseT
504 bytes Input
Ethernet – Boot P, Static IP
59