MCJR1S00 DANAHER, MCJR1S00 Datasheet - Page 120

Multifunction Counter

MCJR1S00

Manufacturer Part Number
MCJR1S00
Description
Multifunction Counter
Manufacturer
DANAHER
Datasheet

Specifications of MCJR1S00

No. Of Digits / Alpha
8
Digit Height
7.6mm
Power Consumption
6VA
Counting Speed
10kHz
Operating Temperature Range
0°C To +50°C
Character Size
0.3"
Panel Cutout Width
3.58"
Lead Free Status / RoHS Status
na
R
O
N
E
L
E
C
T
C
I
5
M
R
S
T
E
M
I
T
E
R
S
I
5.26
The SX110 is a microprocessor based control that combines a three
setpoint repeat cycle timer with an internal batch counter. The three
setpoints on the repeat cycle timer function allow overlap or dwell
between the two output timing intervals. The batch counter counts the
number of repeat cycle operations that the timer performs and
automatically stops the timer operation after the user programmed
number of cycles.
The repeat cycle timer can operate as either a DPDT relay output with
ON and OFF times or as two independent SPDT relay interval outputs.
When operated as two interval outputs, a third setpoint is available that
can provide overlap of the two intervals or a dwell period between the
two intervals. The time ranges for the output sequences are individually
programmable. There are four time ranges available for each output
sequence from 99.99 seconds to 99 hours: 59 minutes.
The internal batch counter counts the number of cycles of the repeat
timer output. The batch counter will also automatically stop the timing
operation after the programmed number of cycles. The batch counter
can be set to allow from 1 to 9999 cycles, or it can be set to provide
continuous repeat cycle operation.
The SX110 is housed in a standard DIN case (68mm square cutout).
The case and front bezel require minimal panel space yet provide easy
to use programming keys and an easy to read .36 inch LED display.
The operating modes and time ranges for the unit are programmed
using rocker switches on the back of the unit. This programming
method provides both simplicity and security. The front panel display
has a prompted programming routine that prompts the user when to
program the ON and OFF times as well as the batch counter setpoint.
Some of the other features of the SX110 timer include:
NEMA 4 Hosedown Test rated
Two 5 amp SPDT relay outputs
Four output operating modes
Four independently programmable time ranges for the ON and OFF
times
Time inhibit input
LED indicators for output status
Setpoint to zero or zero to setpoint cycle progress indication
EAGLE SIGNAL
Electronic Timers
VEEDER-ROOT • EAGLE SIGNAL • DYNAPAR
brand
SX110 Three Setpoint Repeat Cycle
SPECIFICATIONS
Time Ranges:
Operating Voltage/Frequency: A6 - 120 VAC, 50/60 Hz
Batch Counter Range: 1-9999 or continuous
Setting Accuracy: Time:
Repeat Accuracy: Time:
Reset Time: 15 ms
Power on Response: 200 ms max.
Operating Temperature: +32° to +122°F (0° to +50°C)
Sensor Power Supply: +12 VDC, 75 milliamps
Output Rating: Relay: 5 amp (resistive), 10 to 264 VAC
Vibration: Unit function is unaffected by 2.5
Static Discharge: Unit function is unaffected by a constant 3600 volt peak,
Transient Protection: Immune to 2500 volts peak transients up to 50
Count: 100%
Count: 100%
tude in both directions of the perpendicular mounting axes imposed from
10 to 100 Hz
60 Hz discharge applied to the grounded front plate at a relative humidity
of less than 25%
microseconds in duration
Three setpoints allow
control of complex
operations... built-in
batch counter can run
a set number of
cycles
Sym.
1
2
3
4
0.001% of setting or 35 ms, whichever is larger
0.05% of setting or 50 ms, whichever is larger
99 Min.: 59 Sec.
99 Hr.: 59 Min.
Maximum
99.99 Sec.
999.9 Sec.
Range
G
sinusoidal vibration magni-
Minimum
Setting
.01 Sec.
.1 Sec.
1 Sec.
1 Min.

Related parts for MCJR1S00