MCJR1S00 DANAHER, MCJR1S00 Datasheet - Page 122

Multifunction Counter

MCJR1S00

Manufacturer Part Number
MCJR1S00
Description
Multifunction Counter
Manufacturer
DANAHER
Datasheet

Specifications of MCJR1S00

No. Of Digits / Alpha
8
Digit Height
7.6mm
Power Consumption
6VA
Counting Speed
10kHz
Operating Temperature Range
0°C To +50°C
Character Size
0.3"
Panel Cutout Width
3.58"
Lead Free Status / RoHS Status
na
R
O
N
E
L
E
C
T
C
I
5
M
R
S
T
E
M
I
T
E
R
S
I
SPECIFICATIONS
Time Ranges:
5.28
The SX410 and the SX430 are dual setpoint timers featuring an inhibit
function that allows the timing operation of the units to be stopped
without resetting the timed value or the outputs.
The many operating modes and the four time ranges are programmed
using rocker switches on the back of the unit. This programming
method provides both simplicity and security. The front panel display
has a prompted programming routine that shows the user how to
program variables such as setpoints and the display cycle progress
direction.
Some of the other features of the SX410 and the SX430 timers include:
NEMA 4 Hosedown Test rated
Eight output operating modes programmable for one or both outputs
Programmable Early Trip prewarn operation
Time inhibit input
LED indicators for output status
Setpoint to zero or zero to setpoint cycle progress indication
Front panel and remote reset inputs
Keypad lock function
Nonvolatile memory (NOVRAM) for program and data retention
Removable terminal blocks for wiring connections
+12 VDC, 75 milliamp sensor power supply
EAGLE SIGNAL
Electronic Timers
VEEDER-ROOT • EAGLE SIGNAL • DYNAPAR
SX410
SX430
Sym.
Sym.
1
2
3
4
1
2
3
4
99 Min.: 59 Sec.
99 Hr.: 59 Min.
Maximum
Maximum
99.99 Sec.
999.9 Sec.
99.99 Min.
999.9 Min.
99.99 Hr.
999.9 Hr.
Range
Range
Minimum
Minimum
Setting
.01 Sec.
Setting
.1 Sec.
.01 Min.
1 Sec.
1 Min.
.1 Min.
.01 Hr.
brand
.1 Hr.
SX410/430 Dual Setpoint Timer
OUTPUT 1 OPERATING MODES
ON-Delay
Interval
The ON Delay and interval modes are also available with totalization. In
Operating Voltage/Frequency: A6 - 120 VAC, 50/60 Hz
Setting Accuracy:
Repeat Accuracy:
Programmed Pulse: .01 to 99.99 seconds
Reset Time: 15 ms
Power on Response: 200 ms max.
Operating Temperature: +32° to +122°F (0° to +50°C)
Sensor Power Supply: +12 VDC, 75 milliamps
Output Rating: Relay: 5 amp (resistive), 10 to 264 VAC
Vibration: Unit function is unaffected by 2.5
Static Discharge: Unit function is unaffected by a constant 3600 volt peak,
Transient Protection: Immune to 2500 volts peak transients up to 50
B6 - 240 VAC, 50/60 Hz
tude in both directions of the perpendicular mounting axes imposed from
10 to 100 Hz
60 Hz discharge applied to the grounded front plate at a relative humidity
of less than 25%
microseconds in duration
Output 1 is energized at the end of the timing cycle.
Output 1 is energized during the timing cycle.
these modes, the display will continue to indicate time registered after
the timing cycle is complete.
RESET TIMING
RESET TIMING TIMING COMPLETE
Dual setpoints with
programmable model
for delay interval,
timed pulse, and
repeat cycle operation
0.05% of setting or 50 ms, whichever is larger
0.001% of setting or 35 ms, whichever is larger
COMPLETE
TIMING
RESET
G
sinusoidal vibration magni-

Related parts for MCJR1S00