PAXCK000 Red Lion Controls, PAXCK000 Datasheet
PAXCK000
Specifications of PAXCK000
Related parts for PAXCK000
PAXCK000 Summary of contents
Page 1
Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL PAX-1/8 DIN PRESET TIMER (PAXTM) & 4 GENERAL DESCRIPTION ® The PAXTM (PAX Timer) and PAXCK (PAX features and performance capabilities to suit a wide range of industrial applications. Both ...
Page 2
ABLE F ONTENTS Ordering Information . . . . . . . . . . . . . . . . . . . 2 General Meter Specifications ...
Page 3
... ETER 1. DISPLAY: 6 digit, 0.56" (14.2 mm) red sunlight readable or standard green LED 2. POWER: AC Versions (PAXCK000, PAXTM000): AC Power 250 VAC, 50/60 Hz Isolation: 2300 Vrms for 1 min. to all inputs and outputs. (300 V working) DC Versions (PAXCK010, PAXTM010): DC Power VDC (Derate operating temperature to 40°C if operating <15 VDC and three Plug-in cards are installed) AC Power: 24 VAC, ± ...
Page 4
O P PTIONAL LUG WARNING: Disconnect all power to the unit before installing Plug-in cards. Adding Option Cards The PAX and MPAX series meters can be fitted with up to three optional plug- in cards. The details for each plug-in ...
Page 5
I NSTALLING THE Installation The meter meets NEMA 4X/IP65 requirements for indoor use when properly installed. The meter is intended to be mounted into an enclosed panel. Prepare the panel cutout to the dimensions shown. Remove the panel latch ...
Page 6
I NSTALLING The Plug-in cards are separately purchased optional cards that perform specific functions. These cards plug into the main circuit board of the meter. The Plug-in cards have many unique functions when used with the meters. CAUTION: The ...
Page 7
POWER WIRING AC Power Terminal 1: VAC Terminal 2: VAC 4.2 TIMER INPUT WIRING Before connecting the wires, the Timer Input logic jumper should be verified for proper position. Two Wire Proximity, Current Source Switch or Isolated Transistor; Current ...
Page 8
SETPOINT (ALARMS) WIRING SETPOINT PLUG-IN CARD TERMINALS 4.5 SERIAL COMMUNICATION WIRING RS232 Communications Terminal Block Connection Figure Extended Comms Connection Figure RS232 is intended to allow two devices to communicate over distances feet. Data Terminal Equipment ...
Page 9
REAL-TIME CLOCK WIRING (PAXCK) Time synchronization between multiple PAXCK meters can be accomplished through a hardware interface on the Real-Time Clock option card. This RS485 type interface allows connection PAXCK meters in a two-wire multidrop ...
Page 10
P ROGRAMMING THE DISPLAY MODE The meter normally operates in the Display Mode. In this mode, the meter displays can be viewed consecutively by pressing the annunciators to the left of the display indicate which display is currently shown; ...
Page 11
MODULE Module 1 is the programming module for the Timer Input Parameters. In the Display Mode, the TMR annunciator indicates the Timer display is currently being shown. An EXCHANGE PARAMETER LISTS feature, which includes the Timer ...
Page 12
FLASH TIMER ANNUNCIATOR This parameter allows the Timer annunciator (TMR) to flash when the Timer is running or stopped/inhibited. Select if a flashing indicator is not desired. TIMER INPUT STATE AT POWER-UP Determines the “Run/Stop” State of the Timer at ...
Page 13
DISPLAY SELECT (Level Active) When active (maintained action), the meter continuously scrolls through all displays that are not “locked-out” in the Display mode. (See Module 3 for Display Lock-out details.) A sub-menu provides Scrolling Speed selection. DISPLAY SELECT (Edge Triggered) ...
Page 14
CHANGE DISPLAY INTENSITY LEVEL When activated (momentary action), the display intensity changes to the next intensity level (of 4). The four levels correspond to Display Intensity Level ( ) settings & 15. The intensity level, when ...
Page 15
MODULE These parameters only appear if a Setpoint option card is installed. Module 3 is the programming module for setting the Display Lock-out Parameters and the “Quick Programming Mode” Value Access Parameters. In the Quick ...
Page 16
MODULE Module 4 is the programming module for the Cycle Counter Parameters. In the Display Mode, the CNT annunciator indicates the Cycle Counter display is currently being shown. An EXCHANGE PARAMETER LISTS feature, which includes the ...
Page 17
Timing Diagrams for Predefined Timer Operating Modes NOTE: Input A is shown as a Sourcing input (active high Sinking input (active low) is used, the logic levels for Input A would be inverted. On-Delay Timing Input A T ...
Page 18
MODULE This module can only be accessed if a Setpoint Card is installed. Module 6 is the programming module for the Setpoint (Alarm) Output Parameters. This programming module can only be accessed if a Setpoint card ...
Page 19
TIME-OUT VALUE to The Time-Out Value only appears when the Setpoint Action ( programmed for Timed Output mode ( ). In this mode, the Time-Out Value is the Setpoint Output time duration, from activation to deactivation. This value is always ...
Page 20
MODULE This module can only be accessed if a Serial Communications Card is installed. * Only appears if the Real-Time Clock Card is installed. Module 7 is the programming module for the Serial Communications Parameters. These ...
Page 21
SERIAL RTC MASTER ADDRESSING A meter, having software code version 2.3 or greater, with a Real Time Clock Card and an RS485 Serial Communication Card installed, can act as a Serial RTC Master, when programmed with meter address 98 or ...
Page 22
... Note: Transmissions are formatted to match the way the parameter is displayed. This includes setpoints. Example: SP1 assigned to RTC. RTC format = 12:00 P. SP1 printout = 12:00 P. Note: When communicating with a Red Lion Controls HMI unit, set programming module 7 (serial This formats the RTC parameters to: Time - 24 Hours, Minutes, Seconds ...
Page 23
COMMUNICATION FORMAT Data is transferred from the meter through a serial communication channel. In serial communications, the voltage is switched between a high and low level at a predetermined rate (baud rate) using ASCII encoding. The receiving device reads the ...
Page 24
TIME DISPLAY FORMAT 12-59p 12-59 Select the format in which the Real-Time Clock Time will be displayed. The format selections depict the range for the RTC Time display, and DO NOT represent the current RTC Time. When the meter is ...
Page 25
... The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property ...
Page 26
PARAMETER VALUE CHART PAXCK Clock Timer 1-INP Timer Input Parameters DISPLAY PARAMETER rANGE TIMER RANGE INP OP TIMER INPUT OPERATION FILtEr TIMER INPUT FILTERING t dir TIMING DIRECTION t Strt TIMER START VALUE (A) TIMER START VALUE (B)* t StOP ...
Page 27
Setpoint (Alarm) Parameters 6-SPt DISPLAY PARAMETER ASM-n SETPOINT ASSIGNMENT ACt-n SETPOINT ACTION OUt-n OUTPUT LOGIC ON-n SETPOINT ON (A) SETPOINT ON (B)* SP-n SETPOINT ON VALUE (A) SETPOINT ON VALUE (B)* OFF-n SETPOINT OFF (A) SETPOINT OFF (B)* SPOF-n SETPOINT ...
Page 28
PAXTM/PAXCK PROGRAMMING QUICK OVERVIEW ...