MCR-FL-C-UI-UI-DCI-24/230 Phoenix Contact, MCR-FL-C-UI-UI-DCI-24/230 Datasheet - Page 2

no-image

MCR-FL-C-UI-UI-DCI-24/230

Manufacturer Part Number
MCR-FL-C-UI-UI-DCI-24/230
Description
INTERFACE ANALOG
Manufacturer
Phoenix Contact

Specifications of MCR-FL-C-UI-UI-DCI-24/230

Input Type
Configurable
Output Type
Configurable
No. Of Output Channels
1
Accuracy
± 0.1%
Supply Voltage Range
20V To 253V
Power Consumption
2VA
Approval Bodies
UL Recognised
External Depth
114.5mm
External
RoHS Compliant
External Length / Height
99mm
Rohs Compliant
Yes
Configurable 3-Way Isolation Amplifier With Long-Range Power Supply – MCR-FL-C-UI-UI-DCI-24/230
2. Technical Data
Connection data
Description
MCR 3-Way isolation amplifier ,
for electrical isolation of analog signals
Technical Data
Input
Input signal
Maximum input signal
Input resistor
Overload capability
Output
Output signal
Maximum output signal
Load
Ripple
General Data
Supply voltage
Current consumption
Transmission error
Temperature coefficient
Cut-off frequency (3 dB)
Response time (10-90%)
Test voltage:
Operational voltage (basic isolation)
Protection against dangerous
shock currents
Degree of protection
Ambient temperature range
Connection method
Mounting position/mounting
Housing material
M 3
GND 1
IN U
GND 1
IN I
1
2
3
4
IN
0.2-2.5
fixed
U,
U
[mm
2
]
flexible
0.2-2.5
OUT
Input/output/power supply
24-14
AWG
5
6
7
8
8
O UT I / U
GND 2
At output voltage
At output current
Current/voltage
Current/voltage
20...253
VAC / DC
GND 3
PHOENIX CONTACT page 2 of 4
Current input
Voltage input
Current input
Voltage input
Housing width 12.5 mm (0.492 in.)
(
Type
MCR-FL-C-UI-UI-DCI-24/230
0…20 mA, 4…20 mA, 0…10 V
reconnectable, switchable / default: 0…20 mA
22 mA / 11 V, approximately
Voltage drop 250 mV, approximately, at 20 mA
1 M , approximately
< 300 mA
Voltage limitation via suppressor diode at 30 V,
maximum permissible continuous current 30 mA
0…20 mA, 4…20 mA, 0…10 V switchable,
default: 0…20 mA
22 mA / 11 V, approximately
600
1 k at 10 V
< 10 mV
20…253 V AC/DC
AC (48…62 Hz): 2 VA / DC, approximately: 1 W, approximately
0.1% of the final value
0.005%/K
< 10 Hz / 10 kHz, approximately, switchable, default: 10 kHz
35 ms / 35 s
4 kV
1 kV AC/DC at surge voltage category II and degree of pollution 2 in
accordance with DIN EN 61 010 Part 1
Increased isolation in accordance with DIN EN 61 010 section 1 and
safe isolation in accordance with VDE 0100 section 410 in the sense of
VDE 0106 section 101 to 300 V AC/DC at overvoltage category II and
degree of pollution 2 between input, output and power supply
IP 20
-10°C (14˚F) to +70°C (158˚F)
Plug-in COMBICON screw-clamp terminal block
Any
Polyamide PA, unarmored
A a F
at 20 mA
eff
MCR-FL-C-UI-UI-DCI-24/230
with configurable inputs and outputs, safe isolation
planned)
and long-range supply
99
28 14 83 8
Order No.
Pcs.
Pkt.
1

Related parts for MCR-FL-C-UI-UI-DCI-24/230