88 970 117 Crouzet USA, 88 970 117 Datasheet - Page 2

M3 MODEM INTERFACE

88 970 117

Manufacturer Part Number
88 970 117
Description
M3 MODEM INTERFACE
Manufacturer
Crouzet USA
Datasheet

Specifications of 88 970 117

Ip/nema Rating
IP20, IP40
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
CSA, UL
External Depth
70mm
External Length / Height
90mm
Mounting Type
DIN Rail
Supply Voltage
RoHS Compliant
Supply Voltage Max
24VDC
Rohs Compliant
Yes
For Use With
Remote Control Application
14/01/2010
Characteristics of the "COM-M3" link with the controller
Characteristics of "Com-M" link with the Modem
Data characteristics
Comments
Processing characteristics of CB, CD, XD & XB product types
Characteristics of products with AC power supplied
Supply
Inputs
Nominal current under 24 V DC
Peak current on energisation
Max. absorbed power
Immunity from micro power cuts
Protection against polarity inversions
Fuse protection
Type of connector
Type of link
Compatibility
Isolation of "Com-M3" connector from the "Com-M"
connector
Isolation of "Com-M3" connector from the ± supply
terminals
Type of connector
Type of link with Modem connector cable
Compatibility
Analogue RTC modem compatibility
GSM modem compatibility
Isolation of "Com-M" connector from the Modem
Isolation of "Com-M" connector from the ± supply
terminals
Data saved by the interface
Backup of data to be sent
LCD display
Programming method
Program size
Program memory
Removable memory
Data memory
Back-up time in the event of power failure
Cycle time
Response time
Clock data retention
Clock drift
Timer block accuracy
Start up time on power up
Nominal voltage
Operating limits
Supply frequency range
Immunity from micro power cuts
Max. absorbed power
Isolation voltage
Input voltage
Input current
Input impedance
Logic 1 voltage threshold
Making current at logic state 1
Logic 0 voltage threshold
Release current at logic state 0
Response time with LADDER programming
30 mA
550 mA
1,1 W
1 ms, repetition 20 times
Yes
1 A fuse
Specific Millenium
Specific Millenium communication protocol
Only with Millenium controllers version ≥ V2.1
Via optocoupler AC 1780 V
Via optocoupler AC 1780 V
Specific Millenium
RS 232 serial (supplied with the communication interface)
Only with Millenium controllers version ≥ V2.1
AT commands
AT commands
Via link cable to Modem (supplied)
Via link cable to Modem (supplied)
Up to 28 messages
1 to 10 recipients (telephone numbers and/or e-mail addresses) per message
Time-stamping of messages to be sent (date and time)
Saving of values on triggering of the message activation condition (digital and numerical values)
Flash memory
88970117: supplied with connecting cable between M3MOD and Modem (Millenium 3 connector to sub DB9)
88970118: supplied with configuaration CD-ROM and telephone cable
88970119: supplied with an antenna, a power cable, and DIN Rail mounting kit
CD, XD: Display with 4 lines of 18 characters
Ladder or function blocks/SFC (Grafcet)
Ladder: 120 lines
Function blocks:
CB, CD: typically 350 blocks
XB, XD: typically 700 blocks
Flash EEPROM
EEPROM
368 bits/200 words
Program and settings in the controller: 10 years
Program and settings in the plug-in memory: 10 years
Data memory: 10 years
Ladder: typically 20 ms
Function blocks: 6 →90 ms
Input acquisition time + 1 to 2 cycle times
10 years (lithium battery) at 25°C
Drift < 12 min/year (at 25°C)
6 s/month (at 25°C with user-definable correction of drift)
1% ± 2 cycle times
< 1,2 s
24 V AC
-15% / +20%
or 20.4 VAC→28.8 VAC
50/60 Hz (+4% / -6%)
or 47→53 Hz/57 < 63 Hz
10 ms (repetition 20 times)
CB12-CD12-XD10-XB10: 4 VA
CB20-CD20: 6 VA
XD10 with extension - XD26-XB26: 7.5 VA
XD26-XB26 with extension: 10 VA
1780 V AC
24 V AC (-15% / +20%)
4,4 mA @ 20,4 V AC
5,2 mA @ 24,0 V AC
6,3 mA @ 28,8 V AC
4.6 kΩ
≥ 14 V AC
>2 mA
≤ 5 V AC
<0.5 mA
50 ms
State 0 →1 (50/60 Hz)
www.crouzet.com