UPL1-1-72-103 AIRPAX, UPL1-1-72-103 Datasheet - Page 22

CIRCUIT PROTECTOR, HYD-MAG, 1P, 250V 10A

UPL1-1-72-103

Manufacturer Part Number
UPL1-1-72-103
Description
CIRCUIT PROTECTOR, HYD-MAG, 1P, 250V 10A
Manufacturer
AIRPAX
Series
UPLr
Datasheet

Specifications of UPL1-1-72-103

Input Voltage Vac
250V
No. Of Poles
1
Current Rating
10A
Interrupting Capacity
5kA
Dielectric Strength
1.5kV
Trip Time
20s
Voltage Rating Vdc
65V
Leaded Process Compatible
Yes
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
188
205/295 DECISION TABLES
How to Order
The ordering code for 205/295 circuit protectors may be
determined by following the steps in the decision tables
shown here.
For example, the code shown is the code for a UL
recognized, two pole protector with series trip, 20
ampere rating at 240Vac max., 50/60Hz short time delay
construction in all poles.
To determine the ordering number for your particular
205/295 unit, simply follow the steps shown. You may use
this number to place an order or as a reference for further
questions you may have.
Notes:
A The most common current values for 100% of rated current are those listed. Please
B All 205/295 protectors are constructed with stainless steel springs and plated parts.
C Terminals will be supplied as #10-32 threaded studs up to 50 amperes. Above this
*Use 0 in place of 1 when ordering switch only.
205
205D
295
-0*
-1
-11
-111
-1111
1
2
consult an Airpax office or sales representative for other values.
As noted in the specifications, all meet normal requirements for moisture and salt
spray resistance. If fungus resistance is required in addition to moisture and salt
spray resistance, special procedures and markings are employed.
amperage terminals will be ¼ -28 threaded studs. All standard units will be supplied
with a hex nut and 2 flat washers on each threaded terminal.
Type
Poles
Second Decision
First
APL/UPL, 205/295 - APL/UPL Decision Tables
Decision
Switch only (no overload sensing)
Single pole unit
Two pole unit
Three pole unit
Four pole unit
Dust sealed protector UL
ratings and construction
Marine ignition protected
Dust sealed protector
D For detailed barrier and wiring information, request Airpax specification AM-433.
E When metric threaded inserts are specified, breakers rated at 50 amperes and
F Available in multi-pole, series only for multiphase applications.
below will be supplied with metric threaded terminals. For breakers rated above
50 amperes, ¼ -28 threaded terminals will be supplied.
Multi-pole units with mixed construction, poles numbered left
to right when viewed from terminal end.
*Can be used for Solder Terminals also.
-0
-1
-1REC4
-1REC5
-1REG4
-1RS
-3
-5
3
Example:
Internal Configuration
Third Decision
205 - 11 -1 - 61- 4 - 203
1
Switch only
(Omit 4th and 5th decisions)
Series
Series with auxiliary switch
*.110 quick connect terminals
Series wtih auxiliary switch
*.187 quick connect terminals
Series with auxiliary switch
(gold contacts) *.110 quick
connect terminals
Series with alarm switch
electrical trip turret terminals
Shunt
Relay
2
3
4
5
http://airpax.sensata.com/
6

Related parts for UPL1-1-72-103