W352-E1-06 Omron, W352-E1-06 Datasheet - Page 39

no-image

W352-E1-06

Manufacturer Part Number
W352-E1-06
Description
Product Manual
Manufacturer
Omron
Datasheet
Basic Functions
Maintenance Functions
Communications Functions
20
Functions Listed by Usage
Set the cycle time to a fixed interval.
Stop PC operation when the cycle time exceeds a
maximum setting.
Keep all outputs ON when PC operation stops.
Retain the contents of I/O memory when starting
operation.
Retain the contents of I/O memory when the PC is
turned on.
Eliminate effects from chattering and external noise.
Record data with time-stamp.
Establish user-defined errors for desired input
conditions. (Fatal and non-fatal errors can be defined.)
Read the number of power interruptions.
Set the startup operating mode.
Read/write I/O memory data and change the operating
mode from a host computer.
Connect to a serial device such as a bar code reader
or serial printer.
Make a high-speed connection with an OMRON
Programmable Terminal.
Make a PC-PC data link connection with another
CPM2A, or a CPM1, CPM1A, CPM2C, SRM1, CQM1,
C200HS, or C200HX/HG/HE PC.
Connect a Programming Console.
Connect a personal computer running
CX-Programmer, SYSMAC Support Software (SSS) or
SYSMAC-CPT Support Software.
Monitor equipment with a Programmable Terminal and
program the PC with a Programming Device.
Reduce both resources and space by using remote
I/O.
Creating a link with a DeviceNet Master.
Usage
Usage
Usage
Set a minimum (fixed) cycle time in the PC Setup.
Set a maximum (watch) cycle time in the PC Setup.
Turn ON the IOM Hold Bit (SR 25212).
Turn ON the IOM Hold Bit (SR 25212).
Turn ON the IOM Hold Bit (SR 25212) and set the PC
Setup (DM 6601) so that the status of the IOM Hold Bit
is maintained at startup.
Set a longer input time constant in the PC Setup.
Clock/calendar function
FAL(06) defines non-fatal errors. (PC operation
continues.)
FALS(07) defines fatal errors. (PC operation stops.)
The number of power interruptions is stored in AR 23.
Set the startup operating mode in the PC Setup
(DM 6600).
Host Link communications (Set the communications
mode to Host Link in the PC Setup.)
No-protocol communications (Set the communications
mode to no-protocol in the PC Setup.)
1:1 NT Link (Set the communications mode to 1:1 NT
Link in the PC Setup.)
1:1 PC Link (Set the communications mode to 1:1 PC
Link in the PC Setup.)
Connect the Programming Console to the Peripheral
port. (The CPU Unit’s Communications Switch setting
has no effect on this connection.)
The computer can be connected to the Peripheral port
or RS-232C port.
(The Host Link settings in the PC Setup are used
when the switch is OFF; the standard Host Link
communications settings are used when the CPU
Unit’s Communications Switch is ON.)
The RS-232C port and Peripheral port can be used
simultaneously.
Use a CompoBus/S Link Unit.
Use a DeviceNet Link Unit.
Function
Function
Function
Section
W353
W353
W353
Page
93
W353
Page
81
W353
Page
93
W353
Page
43
W353
Page
44
Refer
Refer
Refer
to
to
to
1-4