W352-E1-06 Omron, W352-E1-06 Datasheet - Page 45

no-image

W352-E1-06

Manufacturer Part Number
W352-E1-06
Description
Product Manual
Manufacturer
Omron
Datasheet
DM Area Differences
1-6
26
Preparation for Operation
Preparation for Operation
1, 2, 3...
Note CPM1A programs that use the Error Log Area cannot be used in the CPM2A
The following table shows differences in the DM area other than the PC Setup.
without editing the program to change the location of the Error Log Area.
The following table shows differences in the PC Setup.
Follow the steps listed below when setting up a CPM2A system.
Error Log Area
RS-232C Port Servicing Time Setting
RS-232C Port Servicing Time Enable
Pulse Output 0 Coordinate System
Pulse Output 1 Coordinate System
RS-232C Communications Settings Selector
RS-232C Port CTS Control Settings
RS-232C Port Link Words for 1:1 PC Link
RS-232C Port Communications Mode
RS-232C Port Baud Rate
RS-232C Port Frame Format
RS-232C Port Transmission Delay
RS-232C Port Host Link Node Number
RS-232C Port No-protocol Start Code Enable
RS-232C Port No-protocol End Code Enable
RS-232C Port No-protocol Start Code Setting
RS-232C Port No-protocol End Code Setting
or Number of Bytes Received
Peripheral Port No-protocol Start Code Enable
Peripheral Port No-protocol End Code Enable
Peripheral Port No-protocol Start Code Setting
Peripheral Port No-protocol End Code Setting
or Number of Bytes Received
Battery Error Detect Setting
1. System Design
2. Installation
3. Wiring
• Select a CPM2A CPU Unit, Expansion Units and Expansion I/O Units with
• Design external fail-safe circuits such as interlock circuits and limit circuits.
Refer to 2-1 Specifications and 3-1 Design Precautions for details.
• Install the CPU Unit. (Surface-mount or DIN-track installation)
• Install the Expansion Unit(s) and Expansion I/O Unit(s).
Refer to 3-3 Installing the CPM2A and 3-4 Wiring and Connections for de-
tails.
• Wire the power supply and I/O devices.
• Connect communications devices if necessary.
• Connect the Programming Console.
Refer to 3-4 Wiring and Connections for details.
the specifications required in the controlled system.
Function
Function
DM 2000 to DM 2021 DM 1000 to DM 1021
CPM2A
DM 6616 bits 00 to 07 Not
DM 6616 bits 08 to 15 supported
DM 6629 bits 00 to 03
DM 6629 bits 04 to 07
DM 6645 bits 00 to 03
DM 6645 bits 04 to 07
DM 6645 bits 08 to 11
DM 6645 bits 12 to 15
DM 6646 bits 00 to 07
DM 6646 bits 08 to 15
DM 6647
DM 6648 bits 00 to 07
DM 6648 bits 08 to 11
DM 6648 bits 12 to 15
DM 6649 bits 00 to 07
DM 6649 bits 08 to 15
DM 6653 bits 08 to 11
DM 6653 bits 12 to 15
DM 6654 bits 00 to 07
DM 6654 bits 08 to 15
DM 6655 bits 12 to 15
CPM2A
Section
CPM1A
CPM1A
1-6
d

Related parts for W352-E1-06