460-480 Tyco Electronics, 460-480 Datasheet - Page 105

Voltage Transformer

460-480

Manufacturer Part Number
460-480
Description
Voltage Transformer
Manufacturer
Tyco Electronics
Series
460r
Datasheet

Specifications of 460-480

Turns Ratio
4
Transformer Mounting
Chassis
Voltage Ratio
480
Primary Voltages
480V
Power Rating
150VA
Output Voltage
120V
Mounting Type
Foot Mounted
Transformer Type
Voltage
Lead Free Status / RoHS Status
na
Model 109 – Wound Primary
Model 190X – Auxiliary Transformer
MODEL 190
The Model 190 is a low ratio wound primary current transformer, suitable for primary
currents up to 50 amperes. The table below lists the most common current ratings.
MODEL 190X
ANSI Metering Class: 0.3 B0.5
The Model 190X is an auxiliary transformer for use in the secondary of main current
transformers to change the ratio for metering applications. Since the Model 190X is used in
the secondary of another current transformer it has no voltage rating. It is given a 2500
Volt 60Hz high potential test. It is designed to be used on circuits not to exceed 600 Volts
to ground or between windings.
** The circuits of up to five secondaries may be totalised. Equal or unequal line current
190X0100
190X0200
190X0250
190X0500
190X0625
190X1000
190X1250
190X1667
190X2000
190X2395
190X2500
190X2890
190X3000
190X3330
190X3750
190X4000
190X5000
190X5333
Catalogue Number
190–2–XXX
190–4–XXX
transformers can be summed with this transformer. Advise the ratios of the line current
transformers to be totalised. Output terminals are X1–X2.
Catalogue
Number
12.5
30.0
VA for 1% Class
Current Ratio
5:0.100
5:0.200
5:0.250
5:0.500
5:0.625
5:1.000
5:1.250
5:1.667
5:2.000
5:2.395
5:2.500
5:2.890
5:3.000
5:3.330
5:3.750
5:4.000
5:5.000
5:5.330
B0.1
0.6
0.3
190X6250
190X7500
190X8000
190X10000
190X12500
190X15000
190X1500–5
190X1667–5
190X2500–5
190X2875–5
190X7500–5
190X10500–5
190X0500–1
190X0923–1
190X0400–10
190XSUM–2**
190XSUM–3**
190XSUM–4**
190XSUM–5**
Catalogue Number
ANSI metering class at 60Hz
B0.2
0.6
0.3
B0.5
1.2
0.3
*
*
1
4
– 20 stud terminals
B0.9
2.4
0.6
*
Current Ratio
5:6.250
5:7.500
5:8.000
5:10.000
5:12.500
5:15.000
1.500:5
1.667:5
2.500:5
2.875:5
7.500:5
10.500:5
0.500:1
0.923:1
0.400:10
5+5:5
5+5+5:5
5+5+5+5:5
5+5+5+5+5:5
B1.8
1.2
*
CSA 223647
Approvals
Frequency:
5 – 400Hz
Insulation Level
600 Volts, 10kV BIL full wave
Continuous Thermal Current
Rating Factor:
1.33 at 30°C amb., 1.0 at 55°C amb.
• Terminals are brass studs No. 8 – 32
• Order Mounting Bracket Kit
• Approximate weight: 4 lbs
with one flatwasher and regular nut,
for ratios upto 25:5 and 1/4 – 20 studs
for higher ratios
UL 257877
105