BMA150-0330SB0003 BOSCH, BMA150-0330SB0003 Datasheet - Page 13

Daughter Board

BMA150-0330SB0003

Manufacturer Part Number
BMA150-0330SB0003
Description
Daughter Board
Manufacturer
BOSCH
Datasheet

Specifications of BMA150-0330SB0003

Silicon Manufacturer
Bosch
Application Sub Type
Accelerometer - Three-Axis
Kit Application Type
Sensing - Motion / Vibration / Shock
Silicon Core Number
BMA150
Kit Contents
Board
If a not-latched interrupt is generated, the device waits in the normal mode till the interrupt
condition disappears. The minimum duration of interrupt activation is 330µs. If no interrupt is
generated, the sensor IC goes to sleep mode for a defined time (wake_up_pause).
For more details on the wake-up functionality, please refer to chapter 7.3
3.1.5 Wake_up_pause
These bits (address 15h, bit 2 and 1) define the sleep phase duration between each automatic
wake-up.
Table 5: Settings of wake_up_pause
Note: The accuracy of the wake-up timer is about ±30%.
3.1.6 Shadow_dis
BMA150 provides the possibility to block the update of data MSB while LSB are read out. This
avoids a potential mixing of LSB and MSB of successive conversion cycles. When this bit
(address 15h, bit 3) is at 1, the blocking procedure for MSB is not realized and MSB only
reading is possible.
Rev. 1.5
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such
as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
wake_up_pause<1:0>
00
01
10
11
Triaxial, digital acceleration sensor
Sleep phase duration
Data sheet
BMA150
Page 13
2560 ms
320 ms
20 ms
80 ms
Bosch Sensortec
30 May 2008