BMA150-0330SB0003 BOSCH, BMA150-0330SB0003 Datasheet - Page 16

Daughter Board

BMA150-0330SB0003

Manufacturer Part Number
BMA150-0330SB0003
Description
Daughter Board
Manufacturer
BOSCH
Datasheet

Specifications of BMA150-0330SB0003

Silicon Manufacturer
Bosch
Application Sub Type
Accelerometer - Three-Axis
Kit Application Type
Sensing - Motion / Vibration / Shock
Silicon Core Number
BMA150
Kit Contents
Board
3.2.8 HG_thres, HG_hyst, HG_dur, counter_HG
HG_thres (address 0Eh, bits 7-0 / high-g threshold) and HG_hyst (address 11h, bits 5-3 / high-g
threshold hysteresis) define the high-G level and its associated hysteresis. HG_dur (high-g
threshold qualification duration) and counter_HG (address 0Bh, bits 5 and 4 / high-g counter
down register) are used for debouncing the high-g criteria.
Threshold and duration codes define a criterion for interrupt generation when absolute value of
acceleration is high for long enough duration.
The data format is unsigned integer.
HG_threshold criterion_x is true if
HG_threshold interrupt is set if
HG_threshold criterion_x is false if |acc_x | < (HG_thres - 32*HG_hyst) / 255 * range
HG_threshold interrupt is reset if
HG_thres and HG_hyst codes must be chosen to have (HG_thres - 32*HG_hyst) > 0.
When HG_thres criterion becomes active, a counter is incremented by 1 LSB/ms. When the
high-g acceleration interrupt counter value equals (HG_dur+1), an interrupt is generated.
Depending on counter_HG register value, the counter could also be reset or count down when
HG_thres criterion is false.
Table 7: Description of debouncing counter_HG
If latch_INT=0, the interrupt is not a latched interrupt and then it is reset as soon as HG_thres
criterion becomes false. When interrupt occurs, the interrupt counter is reset.
Rev. 1.5
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such
as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
counter_HG<1:0> High acceleration interrupt counter status when
00
01
10
11
Triaxial, digital acceleration sensor
HG_thres criterion is false
Count down by 1 LSB/ms
Count down by 2 LSB/ms
Count down by 3 LSB/ms
|acc_x |
(HG_thres
HG_thres criterion_z) AND interrupt counter = (HG_dur+1)
NOT(HG_thres criterion_x OR HG_thres criterion_y OR
HG_thres criterion_z)
reset
Data sheet
BMA150
Page 16
HG_thres / 255 * range
criterion_x
OR
HG_thres
Bosch Sensortec
criterion_y
30 May 2008