3G3JV-PFI1010-E Omron, 3G3JV-PFI1010-E Datasheet

no-image

3G3JV-PFI1010-E

Manufacturer Part Number
3G3JV-PFI1010-E
Description
FILTER, 0.1-0.4KW, 1 PHASE MOTOR
Manufacturer
Omron
Datasheet

Specifications of 3G3JV-PFI1010-E

Filter Type
EMI
Current Rating
10A
Svhc
No SVHC (15-Dec-2010)
External Depth
45mm
External Length / Height
169mm
External Width
71mm
No. Of Phases
1
Power Rating
0.55kW
Termination Type
Wire
Capacitance
0µF
The 3G3JV is a miniature high- -efficiency frequency inverter with an
excellent price- - performance relationship.
The generous dimensions of the power section ensure a high starting
torque and low susceptibility to overload which increases machine
reliability.
Its many programmable inputs and outputs, an integrated potentio-
meter for speed control and various monitor functions provide the
inverter with high versatility and flexibility. The multifuntion inputs can
be set to either PNP or NPN. The analog inputs can be 0..10 V,
4..20 mA or 0..20 mA.
Features
To comply with relevant EMC guidelines it is imperative for
frequency inverters to be operated with line filters.
- - exceptionally compact design
- - integrated reference value potentiometer
- - modbus interface, optional
- - 8 fixed frequencies
- - 4 multifunction digital inputs
- - 1 multifunction digital output
- - 1 multifunction analog output
- - Approval: CE, UL, CSA
General
System architecture
Voltage
supply
L1
L2
L3
PE
Shielding
footprint type
Line filter,
Contact surfaces to
the metal plate
Shielding
3G3JV inverter
Cabinet assembly
on metal plate
U
V
W
PE
M
13

Related parts for 3G3JV-PFI1010-E

3G3JV-PFI1010-E Summary of contents

Page 1

... General The 3G3JV is a miniature high- -efficiency frequency inverter with an excellent price- - performance relationship. The generous dimensions of the power section ensure a high starting torque and low susceptibility to overload which increases machine reliability. Its many programmable inputs and outputs, an integrated potentio- meter for speed control and various monitor functions provide the inverter with high versatility and flexibility ...

Page 2

... 3G3JV- -PFI2010- -E 3G3JV- -A2002 3G3JV- -PFI2010- -E 3G3JV- -A2004 3G3JV- -PFI2010- -E 3G3JV- -A2007 3G3JV- -PFI2010- -E 3G3JV- -A2015 3G3JV- -PFI2020- -E 3G3JV- -A2022 3G3JV- -PFI2020- -E 3G3JV- -A2040 3G3JV- -PFI2030- -E 3G3JV- -A4002 3G3JV- -PFI3005- -E 3G3JV- -A4004 3G3JV- -PFI3005- -E 3G3JV- -A4007 3G3JV- -PFI3010- -E 3G3JV- -A4015 3G3JV- -PFI3010- -E ...

Page 3

... Supply Rated input voltage and frequency Max. voltage variation Max. frequency variation * With single phase connection for JV- -A2 type s 400 V class Three phase: 3G3JV- -A4 Maximum allowed motor output Output data Output data Inverter output Output rated current Max. output voltage Output frequencies ...

Page 4

... Technical data (continued) General data Control functions Control functions Control method Output frequency range Frequency precision Frequency precision Resolution of frequency Resolution of frequency reference value reference value Resolution of output frequency Overload capacity Frequency reference value Braking torque Braking torque (short- -time peaks) ...

Page 5

... Forwards- -Start- -Stop S1 Multifunction input 1 S2 Multifunction input 2 S3 Multifunction input 3 S4 Multifunction input 4 S5 Reference potential Multifunction inputs FS (+12 VDC) Frequency reference FR value 0..10 V, 4.. 3G3JV inverter Multifunction analog output 0..10 VDC AC 0V Multifunction relay output MA Closer MB Opener MC Common contact ...

Page 6

... Line filter 3G3JV- -PFI_ Product number 71 51 169 156 45 1010E 91 169 156 50 111 1020E 62 194 181 50 82 2010E 91 169 ...

Page 7

... Maximum output frequency 50,0..400 Hz Max. output voltage 1..255 V Corner frequency 0,2..400 Hz Middle output frequency 0,1..399,9 Hz Output voltage at middle output 0,1..255 V frequency Minimum output frequency 0,1..10 Hz Output voltage at minimum output 0.1..50 V frequency Acceleration time 1 0,0..999 s 3G3JV inverter 19 ...

Page 8

... Set of parameters (continued) Parameter Default MODBUS number setting address n017 10.0s 111H n018 10.0s 112H n019 10.0s 113H n020 0 114H n021 0.00 Hz 115H n022 0.00 Hz 116H n023 0.00 Hz 117H n024 0.00 Hz 118H n025 0.00 Hz 119H n026 0.00 Hz 11AH n027 ...

Page 9

... Level of protection against sweep 30..200% of the rated current during operation Frequency recognition level 0,0..400 Hz Over- -torque recognition 3G3JV inverter Fault Inverter in operation Reference value reached Zero frequency reached Output frequency ³ n058 Output frequency £n058 Over- -torque (NO) Over- -torque (NC) Output frequency Motor current ...

Page 10

... Set of Parameters (continued) Parameter Default MODBUS number setting address n060 160% 13CH n061 0.1s 13DH n062 0 13EH n063 1.0 13FH n064 depending on 140H model n065 depending on 141H model n066 0.0 142H n067 2.0s 143H n068 0 144H n069 0 145H n070 ...

Related keywords