3G3JV-PFI1010-E Omron, 3G3JV-PFI1010-E Datasheet - Page 4

no-image

3G3JV-PFI1010-E

Manufacturer Part Number
3G3JV-PFI1010-E
Description
FILTER, 0.1-0.4KW, 1 PHASE MOTOR
Manufacturer
Omron
Datasheet

Specifications of 3G3JV-PFI1010-E

Filter Type
EMI
Current Rating
10A
Svhc
No SVHC (15-Dec-2010)
External Depth
45mm
External Length / Height
169mm
External Width
71mm
No. Of Phases
1
Power Rating
0.55kW
Termination Type
Wire
Capacitance
0µF
3G3JV inverter
General data
Control functions
Control functions
Protective
Protective
functions
functions
Functions
Functions
Ambient conditions
Ambient conditions
Ambient conditions
16
Technical data (continued)
Control method
Output frequency range
Frequency precision
Frequency precision
Resolution of frequency
Resolution of frequency
reference value
reference value
Resolution of output frequency
Overload capacity
Frequency reference value
Braking torque
Braking torque
(short- -time peaks)
(short- -time peaks)
Motor overload protection
Instantaneous overcurrent
protection
Overload protection
Overvoltage protection
Undervoltage protection
Momentary power interruption
compensation (selection)
Cooling fin overheating
Ventilator control
Grounding protection
Digital inputs
Digital outputs
Analog output
Braking and acceleration
times
Display
Display
Type of protection
Cooling
Ambient temperature
Ambient temperature
Air humidity
Storage temperature
Assembly
Position height
Vibration resistance
Sinusoidal PWM, terminal Volts/Hertz control
0,1..400 Hz
digital reference value: ±0,01 % (- -10..+50° C)
analogue reference value: ±0,5% (25 ±10° C)
digital reference value: 0,01 Hz (<100 Hz), 0.1 Hz (>100 Hz)
analogue reference value 1/1000 of maximum frequency
0,01 Hz
150%/60 s
0..10 V (20 kW ), 4- -20 mA (250 W ), 0- -20 mA (250 W )
up to 200 W
550W, 1,1 kW
1,5 kW
>1,5 kW
Sustained braking torque approx. 20% without, 150% with external braking resistor
electronically adjustable motor protection
stops at approx. 250% of rated output current
stops at 150% of rated current for 1 min.
stops when maincircuit DC voltage is approx. 410 V
stops when maincircuit DC voltage is approx. 160 V
stops for 15 ms or more by setting the inverter to momentary power interruption mode,
operation can be continued if power is restored within approx. 0,5 sec.
detects at 110 ° C ± 10 ° C
electronic protection against blocking
protection at rated output current level
4 multifunction digital input
1 multifunction digital output
1 multifunction analog output (0..10 V)
0,0..999 s
frequency, current or reference value by selection
error and status LED
IP20, wall installation
separate cooler for 0,75 kW (200 V)
open installation:
wall installation:
95% (without condensation)
- -20° C to +60° C
in cabinet, free of dust and corrosive gases
max. 1000 m
1 g at <20 Hz, 0,2 g at <50 Hz
150%
100%
50%
20%
- -10° C to 50° C
- -10° C to 40° C

Related parts for 3G3JV-PFI1010-E