3G3JV-PFI1010-E Omron, 3G3JV-PFI1010-E Datasheet - Page 9

no-image

3G3JV-PFI1010-E

Manufacturer Part Number
3G3JV-PFI1010-E
Description
FILTER, 0.1-0.4KW, 1 PHASE MOTOR
Manufacturer
Omron
Datasheet

Specifications of 3G3JV-PFI1010-E

Filter Type
EMI
Current Rating
10A
Svhc
No SVHC (15-Dec-2010)
External Depth
45mm
External Length / Height
169mm
External Width
71mm
No. Of Phases
1
Power Rating
0.55kW
Termination Type
Wire
Capacitance
0µF
Parameter
number
n040
n041
n042
n043
n044
n045
n046
n047
n048
n049
n050
n051
n052
n053
n054
n055
n056
n057
n058
n059
Set of Parameters (continued)
Default
setting
1
100%
0%
0.1s
0
1
4
0
0
0.0 Hz
0.0 Hz
0.0 Hz
50%
0.5s
0.5s
0
170%
160%
0.0 Hz
0
MODBUS
address
128H
129H
12AH
12BH
12CH
12DH
12EH
12FH
130H
131H
132H
133H
134H
135H
136H
137H
138H
139H
13AH
13BH
Name
Multifunction output
MA, MB, MC (relay)
Reinforcement of analog input
Offset of analog input
Filter time for analog input
Analog input holding
Analog input reinforcement
Clock frequency
Operation after short voltage
breakdown
New start attempts after error
Gating frequency 1
Gating frequency 2
Bandwidth of gating frequencies
Current for d.c. braking
d.c. braking time at Stop
d.c. braking time at Start
Protection against sweep on
braking
Level of protection against sweep
on accelerating
Level of protection against sweep
during operation
Frequency recognition level
Over- -torque recognition
Adjustment range
0
1
2
3
4
5
6
7
10 Alarm
11 Base block
12 Run mode
13 Ready for operation
14 active during error reset
15 under- -voltage recognised
16 Reverse direction
17 Speed search
18 Data transfer via ModBus
0..255%
0.00..2.00s
0
1
0,00..2,00
1
2
3
4
7
8
9
0
1
2
0..10
0,0..400 Hz
0,0..400 Hz
0,0..25,5 Hz
0..100 % of the inverter rated current
0,0..25,5 s
0,0..25,5 s
0
1
30..200% of the rated current
30..200% of the rated current
0,0..400 Hz
0
1
2
3
4
- -99..99%
Fault
Inverter in operation
Reference value reached
Zero frequency reached
Output frequency ³ n058
Output frequency £n058
Over- -torque (NO)
Over- -torque (NC)
Output frequency
Motor current
2,5 kHz
5,0 kHz
7,5 kHz
10 kHz
12 x motor frequency
24 x motor frequency
36 x motor frequency
Error signal
Error signal after >0.5 s
Operation is continued
Enabled
Disabled (braking resistor!!)
Disabled
Detection only when speed coincides
and operation continues
Detection only when speed coincides
and output shut off
Always detection, issues alarm
Always detection, output shut off
3G3JV inverter
21

Related parts for 3G3JV-PFI1010-E