KSZ8842-32MVLI Micrel Inc, KSZ8842-32MVLI Datasheet - Page 120

2-Port Ethernet Switch/Repeater + Generic (32-bit) Bus Interface( )

KSZ8842-32MVLI

Manufacturer Part Number
KSZ8842-32MVLI
Description
2-Port Ethernet Switch/Repeater + Generic (32-bit) Bus Interface( )
Manufacturer
Micrel Inc
Datasheet

Specifications of KSZ8842-32MVLI

Controller Type
Ethernet Switch Controller
Interface
PCI
Voltage - Supply
3.1 V ~ 3.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
128-LQFP
Number Of Primary Switch Ports
2
Internal Memory Buffer Size
32
Operating Supply Voltage (typ)
3.3V
Fiber Support
Yes
Integrated Led Drivers
Yes
Phy/transceiver Interface
MII
Power Supply Type
Analog/Digital
Data Rate (typ)
10/100Mbps
Vlan Support
Yes
Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Pin Count
128
Mounting
Surface Mount
Jtag Support
No
Operating Supply Voltage (max)
3.5V
Operating Supply Voltage (min)
3.1V
Operating Temperature Classification
Industrial
Data Rate
100Mbps
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
576-1635 - BOARD EVALUATION KSZ8842-16MVL
Current - Supply
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
576-3270

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KSZ8842-32MVLI
Manufacturer:
Micrel
Quantity:
915
Part Number:
KSZ8842-32MVLI
Manufacturer:
Micrel Inc
Quantity:
10 000
Dynamic MAC Address Table
The Dynamic MAC address is a read only table.
Dynamic MAC Address Lookup Example:
Micrel, Inc.
Bit
71
70-67
66
65-56
55-54
53-52
51-48
47-0
October 2007
Dynamic MAC Address Table Read (read the first entry at indirect address offset 0 and retrieve the MAC
table size)
Then
Default Value
1
00
0x0000_0000_
0000
0x000
0x0
Write to reg. IACR with 0x1800 (set indirect address and trigger a read dynamic MAC table operation)
Read reg. IADR1 (dynamic MAC table bits 71-64) // If bit 71 = 1, restart (reread) from this register
Read reg. IADR3 (dynamic MAC table bits 63-48)
Read reg. IADR2 (dynamic MAC table bits 47-32)
Read reg. IADR5 (dynamic MAC table bits 31-16)
Read reg. IADR4 (dynamic MAC table bits 15-0)
R/W
RO
RO
RO
RO
RO
RO
RO
RO
Table 19. Dynamic MAC Address Table Format (1024 Entries)
Description
Data not ready
1: specifies that the entry is not ready, continue retrying until bit is set to 0
0: specifies that the entry is ready
Reserved
MAC empty
1: specifies that there is no valid entry in the table
0: specifies that there are valid entries in the table
No of valid entries
Indicates how many valid entries in the table
0x3ff means 1 K entries
0x001 means 2 entries
0x000 and bit 66 = 0 means 1 entry
0x000 and bit 66 = 1 means 0 entry
Time Stamp
Specifies the 2-bit counter for internal aging.
Source port
Identifies the source port where FID+MAC is learned:
00: port 1
01: port 2
10: port 3
FID
Specifies the filter ID.
MAC Address
Specifies the 48-bit MAC address.