FLUKE-287/FVF Fluke Electronics, FLUKE-287/FVF Datasheet - Page 19

COMBO KIT DMM & ACCESSORY

FLUKE-287/FVF

Manufacturer Part Number
FLUKE-287/FVF
Description
COMBO KIT DMM & ACCESSORY
Manufacturer
Fluke Electronics
Series
FlukeView® Forms, 28xr
Type
Digital (DMM)r
Datasheets

Specifications of FLUKE-287/FVF

Includes
Battery, Case, Clips, Software, Test Leads
Style
Handheld
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
50000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, dB
Features
Backlight, Data Logging, Hold, Memory, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
287/FVF
3340186
614-1151
True-rms Digital Multimeters
Features
The mini-measurement display shows the measurement value of
the primary function, if it is not already shown in the page area of
the display. For example, when the display is frozen for a HOLD,
the mini-measurement display continues to show the input signal
(Live) measurement and a mini z. In addition, the mini-
measurement display will flash, if z (for inputs above 30 volts)
would normally appear in the primary display but is obscured. To
warn of the possibility of blowing a current fuse, the mini-
measurement display also flashes when current measurements
exceed the maximum continuous current levels (see
specifications).
Page Area
The page area of the display is where the main meter content is
displayed. The primary display (upper half of the page area) is
where the most important value of the selected function is
shown. The secondary display contains the bar graph and values
that may be measured in addition to the primary function value.
For example, with frequency measurement selected in Vac, the
frequency value will appear in the primary display with the ac
voltage value in the secondary display.
Softkey Labels
Labels for the four function softkeys (F1 through F4) appear in
the bottom row of the display. These labels will change based on
the function and/or menu selection.
Adjusting Display Contrast
When not selecting items on a menu or inputting data, pressing
7 increases display contrast and pressing 8 decreases it.
9