FLUKE-287/FVF Fluke Electronics, FLUKE-287/FVF Datasheet - Page 38

COMBO KIT DMM & ACCESSORY

FLUKE-287/FVF

Manufacturer Part Number
FLUKE-287/FVF
Description
COMBO KIT DMM & ACCESSORY
Manufacturer
Fluke Electronics
Series
FlukeView® Forms, 28xr
Type
Digital (DMM)r
Datasheets

Specifications of FLUKE-287/FVF

Includes
Battery, Case, Clips, Software, Test Leads
Style
Handheld
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
50000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, dB
Features
Backlight, Data Logging, Hold, Memory, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
287/FVF
3340186
614-1151
287/289
Users Manual
Measuring Temperature
The Meter uses an 80BK-A Integrated DMM Temperature Probe
or other type-K temperature probe for measuring temperature.
To measure temperature, set up the Meter as shown in
Figure 14. Press the softkey labeled Menu and move the menu
selector to the menu item labeled Temp. Press the softkey
labeled F for temperature in Fahrenheit or C for Celsius.
The primary display normally shows temperature or the message
“Open Thermocouple”. The open thermocouple message may be
due to a broken (open) probe or because no probe is installed
into the input jacks of the Meter. Shorting the W terminal to
the COM terminal will display the temperature at the Meter
terminals.
28
To avoid the potential for fire or electric shock, do
not connect the thermocouple to electrically live
circuits.
A Meter classified as “SI” will not have an F selection.
R is disabled when the Meter is in the Temperature
function.
XW Warning
Note
Note
Menu
8:10pm
Figure 14. Temperature Measurement
26.5
Save
+8.0 Offset
Offset
06/13/07
C
Setup
Thermocouple
80BK Type K
Probe
Vent
Pipe
or
est17.eps