FLUKE-88-5 Fluke Electronics, FLUKE-88-5 Datasheet - Page 35

no-image

FLUKE-88-5

Manufacturer Part Number
FLUKE-88-5
Description
MULTIMETER AUTOMOTIVE 88V
Manufacturer
Fluke Electronics
Series
8xr
Type
Digital (DMM)r
Datasheets

Specifications of FLUKE-88-5

Includes
Battery, Hanger, Temperature Probe, Test Leads
Style
Handheld
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
20000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Backlight, Hold, Min/Max/Ave
Ranging
Auto/Manual
Response
Average
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2550519
5.
6.
7.
The following are some tips for measuring current:
Break the circuit path to be tested. Touch the black
probe to the more negative side of the break; touch
the red probe to the more positive side of the break.
Reversing the leads will produce a negative reading,
but will not damage the Meter.
Turn on power to the circuit; then read the display.
Be sure to note the unit given at the right side of the
display ( A, mA, or A).
Turn off power to the circuit and discharge all high-
voltage capacitors. Remove the Meter and restore
the circuit to normal operation.
If the current reading is 0 and you are sure the Meter
is set up correctly, test the Meter's fuses as
described under "Testing the Fuses".
A small voltage drop across a current meter input
may effect operation of the measured circuit. You
can calculate this burden voltage using the values
listed in the specifications in Table 15.
Making Measurements
25