FLUKE-88-5 Fluke Electronics, FLUKE-88-5 Datasheet - Page 77

no-image

FLUKE-88-5

Manufacturer Part Number
FLUKE-88-5
Description
MULTIMETER AUTOMOTIVE 88V
Manufacturer
Fluke Electronics
Series
8xr
Type
Digital (DMM)r
Datasheets

Specifications of FLUKE-88-5

Includes
Battery, Hanger, Temperature Probe, Test Leads
Style
Handheld
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
20000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Backlight, Hold, Min/Max/Ave
Ranging
Auto/Manual
Response
Average
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2550519
Size with Holster and Flex-Stand:.............................2.06 in x 3.86 in x 7.93 in (5.2 cm x 9.8 cm x 20.1 cm)
Weight: ........................................................................12.5 oz (355 g)
Weight with Holster and Flex-Stand: ........................22.0 oz (624 g)
Safety: .........................................................................Complies with ANSI/ISA S82.01-2004, CSA 22.2 No. 1010.1:2004 to
Detailed Specifications
For all detailed specifications:
Accuracy is given as
90 %, for a period of one year after calibration. AC conversions are ac coupled and are average responding, rms indicating.
K
1.
2.
Function
1
Below a reading of 200 counts, add 10 counts.
Frequency range: 1 kHz to 2.5 kHz.
600.0 mV
6.000 V
60.00 V
600.0 V
1000 V
Range
([% of reading] + [number of least significant digits]) at 18° C to 28° C, with relative humidity up to
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
Table 12. AC Voltage Function Specifications
50 Hz - 60 Hz
1000 V Overvoltage Category III, IEC 664 to 600 V Overvoltage
Category IV. UL listed to UL61010-1. Licensed by TÜV to EN61010-1.
(0.5 % + 4)
(0.5 % + 2)
(0.5 % + 2)
(0.5 % + 2)
(0.5 % + 2)
30 Hz - 1 kHz
Accuracy
(1.0 % + 4)
(1.0 % + 4)
(1.0 % + 4)
(1.0 % + 4)
(1.0 % + 4)
1 kHz - 5 kHz
unspecified
(2.0 % + 4)
(2.0 % + 4)
(2.0 % + 4)
(2.0 % + 4)
Specifications
2
67