DRT2-OD32BV-1 Omron, DRT2-OD32BV-1 Datasheet - Page 96
DRT2-OD32BV-1
Manufacturer Part Number
DRT2-OD32BV-1
Description
32 Out Vert MIL Connector PNP
Manufacturer
Omron
Datasheet
1.DRT2-OD16.pdf
(600 pages)
Specifications of DRT2-OD32BV-1
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
- Current page: 96 of 600
- Download datasheet (13Mb)
I/O Indicator Status when Short-circuit is Detected (Environment-resistive Terminal Input Units)
SHT0 Indicator Status when Short-circuit Is Detected (Sensor Connector Terminal Input Units and I/O
Units)
I/O Indicator Status when Short-circuit is Detected (Screw-less Clamp Terminal Input Units, Mixed
Units)
Functions of General-purpose Slaves and Environment-resistive Slaves
Note
Note Use a Power Supply Unit with a rated power supply of 50 W for the communi-
power output to the connector where the short-circuit was detected will turn
ON.
cations power supply. A short-circuit is detected when the Unit's sensor power
output current reaches or exceeds 100 mA per input connector. When a short-
circuit occurs, the communications power supply may be temporarily inter-
rupted. After a short-circuit has been detected, the power will be automatically
restored, but during the power interruption use an external circuit in the con-
figuration to make sure the system is operating safely.
Use the following equations to calculate the sensor’s current consumption.
Total network current = Total Unit current consumption + Total sensor current
consumption
Communications power supply capacity ≥ (Total network current + Short-cir-
cuit detection current) x (=100 mA) x (DeviceNet network voltage)
The box indicates the number of the corresponding connector.
1. Refer to SECTION 6 Environment-resistive Slaves for the position of the
2. After a sensor short-circuit is detected, a delay of up to 1.2 s will occur be-
This indicator lights red when a short-circuit error is detected.
This indicator lights red when a short-circuit error is detected.
Lit red.
0 to 15
Environment-resistive Terminal, Sensor Connector
Terminal, or Screw-less Clamp Terminal
Sensor
Short-
circuit
actual indicator.
fore the Sensor Power Shorted Flag is turned ON.
-A
-B
Has the sensor power
shorted?
Section 4-3
75
Related parts for DRT2-OD32BV-1
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
DRT2 Mix IO E-Con 8in/out PNP
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 16 OutMIL Conn Cable With
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 16 In MIL Connector NPN
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 16 In MIL Connector PNP
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 16 In MIL Conn Cable With
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 16 In MIL Conn Cable With
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 Mix IO E-Con8 In/out, NPN
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DRT2 8 Out TermOutal NPN
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: