... Rated voltage Auto-reset Inverse (+/-) 24 VAC/VDC + common Manual-reset Inverse (+/-) + common Auto-reset --- 24 VDC Inverse (+/-) 24 VAC/VDC + common Manual-reset Inverse (+/-) + common 5. Miscellaneous A: Auto-reset, inverse (+/-) input B: Auto-reset, + common input C: Manual-reset, inverse (+/-) input D: Manual-reset, + common input 2 Category Part number 4 G9SB-2002-A G9SB-200-B G9SB-2002-C G9SB-200-D 3 G9SB-3010 4 G9SB-3012-A G9SB-301-B G9SB-3012-C G9SB-301-D ...
Page 2
... The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked. G9SB-3010 1.7 W max. G9SB-3010 60 mA max. (See Note.) G9SB-3010 G9SB-3010 2 2 Approx. 135 g 3 G9SB-301 - 1.7 VA/1.7 W max. G9SB-301 - 30 mA max. G9SB-301 - G9SB-301 - Approx. 120 g ...
Page 3
... G9SB-2002-A (24 VAC/VDC) or G9SB-3012-A (24 VAC/VDC) with 2-Channel Limit ■ Switch Input/Auto-reset Open Control circuit Note: External connections and timing charts for G9SB-200-B/301-B models are the same as those for G9SB-2002-A/3012-A models. G9SB-2002-C (24 VAC/VDC) or G9SB-3012-C (24 VAC/VDC) with 2-Channel ■ Emergency Stop Switch Input/Manual-reset Feedback loop Control circuit Note: External connections and timing charts for G9SB-200-D/301-D models are the same as those for G9SB-2002-C/3012-D models ...
Page 4
... G9SB G9SB-200-D (24 VAC/VDC) or G9SB-301-D (24 VAC/VDC) with 2-Channel Safety Area ■ Sensor/Manual-reset Emitter Receiver F3S-A Shield Red Red/black Note: 1. Connect E1 to model other than the F3S-A. 2. Only the G9SB-301-D model has terminals 33-34 and 41-42. G9SB-3010 (24 VDC) with 2-Channel Limit Switch Input/Auto-reset ■ ...
Page 5
... G9SB Dimensions Unit: mm G9SB-200 - ■ G9SB-3010 100 max. G9SB-301- ■ 100 max. 2x5=10 112 max. 18 max. (Average: 17.5) 3x5=15 112 max. 23 max. (Average: 22.5) 6 Terminal Arrangement G9SB-200 - G9SB-3010 (green) (green) (orange) (orange) (orange) (orange) Terminal Arrangement G9SB-200 - (green) (orange) (orange) ...
Page 6
... G9SB Installation Internal Connections ■ G9SB-2002-A/C (24 VAC/VDC) G9SB-3012-A/C (24 VAC/VDC) G9SB-3010 (24 VDC) Note: 1. For 1-channel input with G9SB- models for 1-channel input. 2. Only G9SB-301 - models have terminals 33-34 and 41-42. G9SB-200-B/D (24 VAC/VDC) G9SB-301-B/D (24 VAC/VDC) -B/D models, short terminals T12 and T22 not possible to wire G9SB- ...
Page 7
... Auto Reset* T31 T31 S3 T32 T32 *Auto and Manual reset is model specific External Device Monitoring T32 *KM1 *KM2 *Add N.C. contacts of external devices in series with T32 G9SB-_-B/D G9SB-_-B/D 2 Channel Input (1 +ve) (2 PNP, Solid State) T12 T11 T12 S1 T22 T22 *A2 *DC models only 8 ...
Page 8
... Stranded wire: 0 Solid wire: 0.2 to 2.5 mm Tighten each screw to a torque of 0.5 to 0.6 N·m, or the G9SB may malfunction or generate heat. External inputs connected to T11 and T12 or T21 and T22 of the G9SB must be no-voltage contact inputs. Applicable Safety Category ■ ...