G9SB-2002-C Sti (Scientific Technologies, Inc.), G9SB-2002-C Datasheet
G9SB-2002-C
Specifications of G9SB-2002-C
Related parts for G9SB-2002-C
G9SB-2002-C Summary of contents
Page 1
... VAC/VDC + common Manual reset Inverse + common None: 1-channel or 2-channel input possible 0: None (direct breaking) 2: 2-channel input A: Auto-reset, inverse input B: Auto-reset, + common input C: Manual reset, inverse input D: Manual reset, + common input G9SB-2002-A 4 G9SB-200-B G9SB-2002-C G9SB-200-D G9SB-3010 3 (See note.) G9SB-3012-A 4 G9SB-301-B G9SB-3012-C G9SB-301-D ...
Page 2
... G9SB Safety Relay Unit I 24 VAC/VDC: 24 VAC, 50/60 Hz, or 24VDC 24 VDC: 24 VDC 85% to 110% of rated power supply voltage 1.6 VA/1.4 W max max. Indicates the current between terminals A1 and A2. 250 VAC VDC The contact resistance was measured with VDC using the voltage-drop method. ...
Page 3
... Control SA circuit T21 T22 External connections and timing charts for G9SB-200-D/301-D models are the same as those for G9SB-2002-C/3012-D models. This circuit conforms to EN954-1 Safety Category 4. Limit switches S1 and S2 K1 and K2 (NC) K1 and K2 (NO) KM1 KM2 KM1 and KM2 (NC) Feedback loop KM1 and KM2 (NO) ...
Page 4
... S1. F3SN-A: Safety Area Sensor S1: Reset switch KM1 and KM2: Magnetic Contactor M: 3-phase motor E1: 24-VDC power supply (S82K) Only the G9SB- 301-D model has terminals 33-34 and 41- KM1 42. Wiring is shown for when the KM2 F3SN-A auxiliary output ...
Page 5
... Limit switches S1 and S2 K1 and K2 (NC) K1 and K2 (NO) KM1 and KM2 (NC) KM1 and KM2 (NO KM1 KM2 KM1 KM2 M G9SB Safety Relay Unit S1: Safety limit switch with direct opening mechanism (NC) (D4B-N, D4N, D4F) S2: Limit switch (NO) KM1 and KM2: Magnetic Contactor M: 3-phase motor ...
Page 6
... G9SB Safety Relay Unit @ @ 83 18 2.5 2 × 100 max. 18 max. (Average: 17. 2.5 3 × 100 max max. (Average: 22. T31 T11 T12 A1 PWR (green) K1 (orange) K2 (orange) T21 T22 T32 112 max. 2 T11 T12 T31 112 max. 2.6 (green) PWR (orange (orange) T21 T22 T32 ...
Page 7
... Control SA K2 circuit For 1-channel input with G9SB-@@@-B/D models, short terminals T12 and T22 not possible to wire G9SB- @@@2-A/C models for 1-channel input. Always provide a protective ground externally, e.g., on the power supply. * Only G9SB-301@-@ models have terminals 33-34 and 41-42 ...
Page 8
... Stranded wire: 0 Solid wire: 0.2 to 2.5 mm Tighten each screw to a torque of 0.5 to 0.6 N·m, or the G9SB may malfunction or generate heat. External inputs connected to T11 and T12 or T21 and T22 of the G9SB must be no-voltage contact inputs. When mounting multiple Units close to each other, the rated current will ...