CMS02(TE12L) Toshiba, CMS02(TE12L) Datasheet - Page 2

DIODE SCHOTTKY 30V 3A 3-4E1A

CMS02(TE12L)

Manufacturer Part Number
CMS02(TE12L)
Description
DIODE SCHOTTKY 30V 3A 3-4E1A
Manufacturer
Toshiba
Datasheet

Specifications of CMS02(TE12L)

Voltage - Forward (vf) (max) @ If
400mV @ 3A
Voltage - Dc Reverse (vr) (max)
30V
Current - Average Rectified (io)
3A
Current - Reverse Leakage @ Vr
500µA @ 30V
Diode Type
Schottky
Speed
Fast Recovery =< 500ns, > 200mA (Io)
Mounting Type
Surface Mount
Package / Case
3-4E1A (M-Flat)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Reverse Recovery Time (trr)
-
Capacitance @ Vr, F
-
Other names
CMS02TR
Marking
Standard Soldering Pad
Handling Precaution
Schottky barrier diodes have reverse current characteristics compared to other diodes.
There is a possibility SBD may cause thermal runaway when it is used under high temperature or high voltage.
Please take forward and reverse loss into consideration during design.
The absolute maximum ratings denote the absolute maximum ratings, which are rated values and must not be
exceeded during operation, even for an instant. The following are the general derating methods that we recommend
when you design a circuit with a device.
Thermal resistance between junction and ambient fluctuates depending on the device’s mounting condition. When
using a device, design a circuit board and a soldering land size to match the appropriate thermal resistance value.
Please refer to the Rectifiers Databook for further information.
Abbreviation Code
V
I
I
T
F(AV)
FSM
j
RRM
:
1.4
:
S2
:
:
Use this rating with reference to the above. V
this temperature coefficient into account designing a device at low temperature.
We recommend that the worst case current be no greater than 80% of the absolute maximum rating
of I
using an allowable Tamax-I
This rating specifies the non-repetitive peak current. This is only applied for an abnormal operation,
which seldom occurs during the lifespan of the device.
Derate this rating when using a device in order to ensure high reliability. We recommend that the
device be used at a T
F(AV)
3.0
and T
Part No.
CMS02
j
be below 100°C. When using this device, take the margin into consideration by
j
1.4
of below 100°C.
Unit: mm
F(AV)
curve.
2
RRM
has a temperature coefficient of 0.1%/°C. Take
2006-11-13
CMS02