E5-648-C4462 EATON CUTLER HAMMER, E5-648-C4462 Datasheet - Page 11

no-image

E5-648-C4462

Manufacturer Part Number
E5-648-C4462
Description
PRESET COUNTER, 6-DIGIT, 10VDC TO 30VDC
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of E5-648-C4462

No. Of Digits / Alpha
6
Digit Height
9mm
Supply Voltage Range
10VDC To 30VDC
Power Consumption
90W
Counting Speed
50kHz
Operating Temperature Range
-20°C To +65°C
E5-648-C446x electronic preset
counter with four presets (relays)
LCD negative, red-green backlighting
7.8.6.3 Main menu for configuration
Unit of time
Decimal point setting (Resolution)
Set value
Display color (for device E5-648-C446x)
Count mode ADDING with automatic
reset and Total counter
Output 2 (timed signal) active when
main counter = preset value 2
Automatic reset to zero when main
counter = preset value 2
Output 3 active when
main counter ≥ preset value 3
Total counter counts all the
count pulses from the main counter
Output 1 resp. 4 active when
total counter ≥ preset value 1 resp. 4
Manual Reset sets both counters to zero
Electronic reset only sets the main counter
to zero
Main menu for matching the time
ranges and display
Unit of time: seconds
Decimal point setting
determines the resolution
Unit of time: minutes
Decimal point setting
determines the resolution
Unit of time: hours
Decimal point setting
determines the resolution
Unit of time: hrs. min. sec.
Decimal place (determines the resolution)
0
0.0
0.00
0.000
Set value can be programmed
from 000000 to 999999.
A previously programmed
decimal point will be displayed
Display color
Upper line: red
Lower line: red
Display color
Upper line: red
Lower line: green
no decimal place
1 decimal place
2 decimal places
3 decimal places
7.8.6.4 Main menu for reset mode
7.8.6.5 Main menu for preset 1
eaton corporation www.eaton.com
Setting the reset mode
Manual reset (with red key)
and electrical reset (reset input)
No reset possible
(red key and reset input inhibited)
Only electrical reset possible (reset input)
Only manual reset possible (red key)
Main menu for turning preset 1 ON/OFF
ADD mode output operations:
permanent signal at output 1,
becomes active when count ≥ preset 1
SUB mode output operations:
permanent signal at output 1,
becomes active when count ≤ preset 1
ADD mode output operations:
permanent signal at output 1,
becomes passive when count ≥ preset 1
SUB mode output operations:
permanent signal at output 1,
becomes passive when count ≤ preset 1
ADD mode output operations:
timed signal at output 1, becomes
active when count ≥ preset 1.
(Activation only in positive direction)
SUB mode output operations:
timed output at output 1, becomes
active when count ≤ preset 1
(Activation only in negative direction)
ADD mode output operations:
timed signal at output 1, becomes
passive when count ≥ preset 1.
(Deactivation only in positive direction)
SUB mode output operations:
timed output at output 1, becomes
passive when count ≤ preset 1.
(Deactivation only in negative direction)
Instruction leaflet IL05407001E
Effective October 2010
11