E5-648-C4462 EATON CUTLER HAMMER, E5-648-C4462 Datasheet - Page 12

no-image

E5-648-C4462

Manufacturer Part Number
E5-648-C4462
Description
PRESET COUNTER, 6-DIGIT, 10VDC TO 30VDC
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of E5-648-C4462

No. Of Digits / Alpha
6
Digit Height
9mm
Supply Voltage Range
10VDC To 30VDC
Power Consumption
90W
Counting Speed
50kHz
Operating Temperature Range
-20°C To +65°C
Instruction leaflet IL05407001E
Effective October 2010
7.8.6.6 Main menu for preset 2
12
eaton corporation www.eaton.com
ADD mode output operations:
timed signal at output 1, becomes
active with positive direction and
when count ≥ preset 1 and
subsequently active with negative
direction and when count ≤ preset 1
SUB mode output operations:
timed signal at output 1, becomes
active with negative direction and
when count ≤ preset 1 and
subsequently active with positive
direction and when count ≥ preset 1
ADD mode output operations:
timed signal at output 1, becomes
passive with positive direction and
when count ≥ preset 1 and
subsequently passive with negative
direction and when count ≤ preset 1
SUB mode output operations:
timed output at output 1, becomes
passive with negative direction and
when count ≤ preset 1 and
subsequently passive with positive
direction and when count ≥ preset 1
Duration of timed signal of output 1,
programmable from 00.01 to 99.99s
Timed signal is post-triggered
Main menu for preset 2
ADD mode output operations:
permanent signal at output 2, becomes
active when count ≥ preset 2
SUB mode output operations:
permanent signal at output 2, becomes
active when count ≤ zero
ADD mode output operations:
permanent signal at output 2, becomes
passive when count ≥ preset 2
SUB mode output operations:
permanent signal at output 2, becomes
passive when count ≤ zero
ADD mode output operations:
timed signal at output 2, becomes
active when count ≥ preset 2
(Activation only in positive direction).
SUB mode output operations:
permanent signal at output 2,
becomes active when count ≤ zero
(Activation only in negative direction)
ADD mode output operations:
timed signal at output 2, becomes
passive when count ≥ preset 2 (Deactivation
only in positive direction)
SUB mode output operations:
permanent signal at output 2,
becomes passive when count ≤ zero
(Deactivation only in negative direction)
7.8.6.7 Main menu for preset 3 and 4
Only preset 3 is represented here
LCD negative, red-green backlighting
counter with four presets (relays)
ADD mode output operations:
timed signal at output 2, becomes
active with positive direction and
when count ≥ preset 2 and
subsequently with negative
direction and when count ≤ preset 2
SUB mode output operations:
timed signal at output 2, becomes
active with negative direction and
when count ≤ zero and
subsequently with positive
direction and when count ≥ zero
ADD mode output operations:
timed signal at output 2, becomes
passive with positive direction and
when count ≥ preset 2 and
subsequently with negative
direction and when count ≤ preset 2
SUB mode output operations:
timed signal at output 2, becomes
passive with negative direction and
when count ≤ zero and
subsequently with positive
direction and when count ≥ zero
Duration of timed signal of output 1,
programmable from 00.01 to 99.99s
Timed output is post-triggered
Main menu for preset 3 [4]
ADD mode output operations:
permanent signal at output 3 [4], becomes
active when count ≥ preset 3 [4]
SUB mode output operations:
permanent signal at output 3 [4], becomes
active when count ≤ preset 3 [4]
ADD mode output operations:
permanent signal at output 3 [4], becomes
passive when count ≥ preset 3 [4]
SUB mode output operations:
permanent signal at output 3 [4], becomes
passive when count ≤ preset 3 [4]
ADD mode output operations:
timed signal at output 3 [4], becomes
active when count ≥ preset 3 [4].
(Activation only in positive direction)
SUB mode output operations:
timed signal at output 3 [4], becomes
active when count ≤ preset 3 [4].
(Activation only in negative direction)
ADD mode output operations:
timed signal at output 3 [4], becomes
passive when count ≥ preset 3 [4].
(Deactivation only in positive direction)
SUB mode output operations:
timed signal at output 3 [4], becomes
passive when count ≤ preset 3 [4].
(Deactivation only in negative direction)
E5-648-C446x electronic preset

Related parts for E5-648-C4462