DS3112N+W Maxim Integrated Products, DS3112N+W Datasheet - Page 30

no-image

DS3112N+W

Manufacturer Part Number
DS3112N+W
Description
Network Controller & Processor ICs M13-E13-G.747 Mux an d T3-E3 Framer T3-E3
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS3112N+W

Product
Framer
Number Of Transceivers
1
Data Rate
44.736 Mbps
Supply Voltage (max)
3.465 V
Supply Voltage (min)
3.135 V
Supply Current (max)
150 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Signal Name:
Signal Description:
Signal Type:
This signal determines whether the DS3112 will operate in either the T3 mode or the E3 mode. It acts as a
global control bit for the entire DS3112. This signal should be set into the proper state before a hardware
reset is issued via the RST signal. This input is coupled with the G.747E input to create a special test
mode whereby all the outputs are tri-stated
Signal Name:
Signal Description:
Signal Type:
This signal determines whether the DS3112 will operate in either the T3 mode or the G.747 mode. It acts
as a global control bit for the entire DS3112. This signal should be set into the proper state before a
hardware reset is issued via the RST signal. This input is coupled with the T3E3MS input to create a
special test mode whereby all the outputs are tri-stated
Table 2-3. Mode Select Decode
Signal Name:
Signal Description:
Signal Type:
This input should be left open circuited by the user.
Signal Name:
Signal Description:
Signal Type:
All V
Signal Name:
Signal Description:
Signal Type:
3.3V (±5%). All V
T3E3MS
SS
0
0
1
1
0 = T3 Mode
1 = E3 Mode
0 = T3 Mode
1 = G.747 Mode
signals should be tied together.
G.747E
DD
0
1
0
1
signals should be tied together.
T3E3MS
T3/E3 Mode Select Input
Input
G.747E
G.747 Mode Enable Input
Input
TEST
Factory Test Input
Input (with internal 10kΩ pullup)
V
Digital Ground Reference
N/A
V
Digital Positive Supply
N/A
SS
DD
T3 or M13 Operation
G.747 Operation
E3 or E13 Operation
Special Test Mode that tri-states all outputs. JTRST must be driven
low for tri-state operation without power-up. Refer to note for
JTRST signal.
(Table
30 of 133
2-3).
MODE SELECTED
(Table
2-3).
DS3112