9-1393792-0 TE Connectivity, 9-1393792-0 Datasheet - Page 43

Electromechanical Relay DPDT 3A 24VDC 3.872KOhm Through Hole

9-1393792-0

Manufacturer Part Number
9-1393792-0
Description
Electromechanical Relay DPDT 3A 24VDC 3.872KOhm Through Hole
Manufacturer
TE Connectivity
Type
Signal Relayr
Datasheets

Specifications of 9-1393792-0

Contact Arrangement
DPDT
Dc Coil Voltage
24 V
Coil Current
6.2 mA
Mounting
Through Hole
Relay Construction
Non-Latching
Coil Voltage Dc
24V
Contact Form
2 Form C
Voltage Rating (vdc)
220V
Voltage Rating (vac)
250V
Dropout Volt (min)
1.2VDCV
Coil Resistance
3.872kohm
Pick-up Voltage (max)
19.2VDC
Maximum Power Rating
60W/125VA
Operate Time
5ms
Contact Current Rating
3A
Contact Material
AgNi/Au
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
11mm
Product Depth (mm)
10mm
Product Length (mm)
20.2mm
Operating Temp Range
-25C to 85C
Pin Count
8
Mounting Style
Through Hole
Termination Style
PC Pin
Package / Case
DIP
Lead Free Status / Rohs Status
Compliant
Agency Approvals
W58 Series is UL 1077 Recognized as Supplementary Protectors, File
E69543, and CSA Certified as Appliance Component Protectors, File
LR15734.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• 0.5 amp to 30 amp ratings.
• Cannot be manually tripped.
• Button extends for visual trip indication.
• Push button to reset breaker.
• Termination is screw or .250” QC.
Time vs. Current Trip Curve @ +25°C
Electrical Data @ +25°C
Calibration: Breaker will continuously carry 100% of rated load. It may trip
Dielectric Strength: Over 1,500 volts RMS.
Maximum Operating Voltages: 50VDC; 250VAC.
Interrupt Capacity: 2,000 amps at 50VDC (0.5 - 30 amp models).
Resettable Overload Capacity: Ten times rated current.
Dimensions are shown for
reference purposes only.
1000
900
800
700
600
500
400
300
200
100
0
.1
between 101% and 145% of rated load, but must trip at
145% at 25°C.
(A)
1,000 amps at 250VAC (0.5 - 30 amp models).
Note: 30 0amp model not UL or CSA
1
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Time In Seconds
.
10
(A) All 5-30 Amp Models
Overload
1000%
100%
145%
200%
400%
600%
800%
(B)
0.25-0.90 Sec.
0.15-0.65 Sec.
Trip in 1 hour
0.60-1.7 Sec.
1.6-4.5 Sec.
Trip Times
6.0-30 Sec.
No Trip
Catalog 1308242
100
Issued 3-03
(B) All 1-4 Amp Models
Overload
1000%
100%
145%
200%
400%
600%
800%
*No UL/CSA
W58
Push To Reset Only
Thermal Circuit Breaker
Maximum Resistance vs. Current Rating @ +25°C
Mechanical/Environmental Data
Shock: Withstands to 10g.
Endurance Cycling: Over 1,000 cycles at 200% of rated load.
Vibration: Withstands to 10g at 10-55 Hz.
Weight: Less than 1 1/2 oz. (42.5g).
Specifications and availability
subject to change.
Trip in 1 hour
3.0-14.0 Sec.
0.75-4.3 Sec.
0.50-3.4 Sec.
1.4-7.0 Sec.
Trip Times
10-45 Sec.
in Amps
Current
Rating
No Trip
0.5
1
2
3
4
5
6
7
1000
series
Resistance
Ambient Compensation Chart
To use this chart: Read up from the ambient
temperature to the curve, and across to find a correction
factor. Multiply the breaker rating by the correction factor
to determine the compensated rating. Calculate the
overloads in terms of the compensated rating to use the
published trip curve.
Maximum
in Ohms
1.40
1.30
1.20
1.10
1.00
0.90
0.80
0.70
0.60
5.0
1.35
0.32
0.18
0.10
0.026
0.026
0.020
Ambient Temperature In Degrees Centigrade (°C)
–20 –10 0
in Amps
Current
Rating
10 20 30 40 50 60
12
15
20
25
30*
10
8
9
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Resistance
Maximum
in Ohms
0.020
0.020
0.014
0.010
0.010
0.005
0.006
0.004
P&B
107