UJA1061TW,512 NXP Semiconductors, UJA1061TW,512 Datasheet - Page 20

no-image

UJA1061TW,512

Manufacturer Part Number
UJA1061TW,512
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of UJA1061TW,512

Number Of Transceivers
1
Power Down Mode
Sleep/Standby
Operating Supply Voltage (min)
5.5V
Operating Temperature (max)
125C
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant
NXP Semiconductors
UJA1061_6
Product data sheet
Fig 8.
RXDC: wake-up (active LOW)
CANL bias V2/floating/(V2D)
States of the CAN transceiver
V2 : ON/OFF (V2D)
On-line mode
transmitter: OFF
CPNC = 0
6.7.1.1 Active mode
CAN wake-up filter passed
In the System Diagnosis register two dedicated CAN status bits (CANMD) are available to
signal the mode of the transceiver.
In Active mode the CAN transceiver can transmit data to and receive data from the CAN
bus. To enter Active mode the CMC bit must be set in the Physical Layer Control register
and the SBC must be in Normal mode or Flash mode. In Active mode voltage regulator V2
is activated automatically.
The CTC bit can be used to set the CAN transceiver to a Listen-only mode. The
transmitter output stage is disabled in this mode.
After an overload condition on voltage regulator V2, the CTC bit must be cleared for
reactivating the CAN transmitter.
AND CMC = 1
Flash mode
AND CPNC = 0
SBS enters
Normal or
power-on
no activity for t > t
CMC = 0 AND CPNC = 0
All information provided in this document is subject to legal disclaimers.
global wake-up message detected
CANL bias BAT42/floating/(V2D)
RXDC: bit stream/HIGH (V2D)
CANL bias V2/floating/(V2D)
off-line
transmitter: ON/OFF (CTC)
V2 : ON/OFF (V2C/V2D)
V2 : ON/OFF (V2D)
Rev. 06 — 9 March 2010
Off-line mode
transmitter: OFF
Active mode
CPNC = 0 or 1
CPCN = 0 or 1
OR CPNC = 0
RXDC: V1
CPNC = 1
CAN wake-up filter passed
Fault-tolerant CAN/LIN fail-safe system basis chip
AND CPNC = 1
CMC = 1
no activity for t > t
CMC = 0 AND CPNC = 1
CANL bias V2/floating/(V2D)
On-line Listen mode
off-line
V2 : ON/OFF (V2D)
transmitter: OFF
RXDC: V1
CPCN = 1
001aaf003
UJA1061
© NXP B.V. 2010. All rights reserved.
CMC = 1
20 of 77