82P2284BB IDT, Integrated Device Technology Inc, 82P2284BB Datasheet - Page 271

no-image

82P2284BB

Manufacturer Part Number
82P2284BB
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of 82P2284BB

Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
82P2284BB
Manufacturer:
IDT
Quantity:
6
Part Number:
82P2284BBG
Manufacturer:
NS/TI
Quantity:
5 705
E1 FRMR Mode 1 (04EH, 14EH, 24EH, 34EH)
BIT2C:
CASEN:
CRCEN:
CNTNFAS & WORDERR:
TS16C & SMFASC:
C2NCIWCK:
Programming Information
IDT82P2284
Bit Name
This bit determines the criteria of out of Basic frame synchronization.
= 0: 3 consecutive FAS pattern errors lead to out of Basic frame synchronization.
= 1: 3 consecutive FAS pattern errors or 3 consecutive NFAS errors lead to out of Basic frame synchronization.
= 0: Disable searching for the Channel Associated Signaling (CAS) Multi-Frame.
= 1: Enable searching for the Channel Associated Signaling (CAS) Multi-Frame after the Basic frame synchronization is acquired.
= 0: Disable searching for the CRC Multi-Frame.
= 1: Enable searching for the CRC Multi-Frame after the Basic frame synchronization is acquired.
These two bits determine the criteria of FAS/NFAS Bit/Pattern Error generation:
These two bits determine the criteria of out of CAS Signaling Multi-Frame synchronization:
= 0: Stop searching for CRC Multi-Frame alignment pattern in CRC to non-CRC interworking mode.
= 1: Enable searching for CRC Multi-Frame alignment pattern even if CRC to non-CRC interworking has been declared.
Default
Bit No.
Type
WORDERR
TS16C
X
0
1
0
1
0
1
BIT2C
R/W
7
1
CNTNFAS
SMFASC
0
0
1
1
0
1
1
CASEN
R/W
6
1
Each bit error in FAS is counted as an error event.
A FAS pattern error is counted as an error event.
Each bit error in FAS or NFAS error is counted as an error event.
A FAS pattern error or NFAS error is counted as an error event.
2 consecutive CAS Signaling Multi-Frame Alignment Pattern Errors occur.
2 consecutive CAS Signaling Multi-Frame Alignment Pattern Errors occur or all the contents in TS16 are
zeros for one Signaling Multi-Frame.
2 consecutive CAS Signaling Multi-Frame Alignment Pattern Errors occur or all the contents in TS16 are
zeros for two consecutive Signaling Multi-Frames.
CRCEN
R/W
5
1
Out Of CAS Signaling Multi-Frame Synchronization Criteria
CNTNFAS
R/W
4
0
271
QUAD T1/E1/J1 LONG HAUL / SHORT HAUL TRANSCEIVER
Error Generation
WORDERR
R/W
3
0
TS16C
R/W
2
0
SMFASC
R/W
1
0
February 25, 2008
C2NCIWCK
R/W
0
0

Related parts for 82P2284BB