Specifications of PLRXXL-SC-S43-C1

Number Of Receivers
1
Operating Temperature Classification
Commercial
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Lead Free Status / RoHS Status
Supplier Unconfirmed
14
Feature
Component safety
RoHS compliance
Laser eye safety
Electromagnetic Compatibility
Electromagnetic emissions
Electromagnetic immunity
ESD immunity
Radiated immunity
Table 2 Regulatory compliance
3.11
The JDSU 10 Gb/s 850 nm XFP optical transceiver is lead-free and RoHS 6/6 com-
pliant per Directive 2002/95/EC of the European Parliament and of the Council of
27 January 2003 on the restriction of the use of certain hazardous substances in
electrical and electronic equipment.
The JDSU 10 Gb/s 850 nm XFP optical transceiver complies with international
Electromagnetic Compatibility (EMC) and international safety requirements and
standards. EMC performance is dependent on the overall system design. Informa-
tion included herein is intended as a fi gure of merit for designers to use as a basis
for design decisions.
3.12
Recommended PCB layout and host board power supply noise fi ltering are given
in XFP MSA INF8077i Rev. 4.5
Test Method
UL 60950
UL94-V0
IEC 60950
Directive 2002/95/EC
EN 60825
U.S. 21CFR 1040.10
EMC Directive 89/336/EEC
FCC CFR47 Part 15
IEC/CISPR 22
AS/NZS CISPR22
EN 55022
ICES-003, Issue 4
VCCI-03
EMC Directive 89/336/EEC
IEC /CISPR/24
EN 55024
EN 61000-4-2
EN 61000-4-3
ROHS COMPLIANT XFP OPTICAL TRANSCEIVER – 850NM
FOR UP TO 300M REACH
Regulatory compliance
PCB Layout
Performance
UL File E209897
TUV Report/Certifi cate (CB scheme)
Compliant per the Directive 2002/95/EC of the European
Parliament and of the Council of 27 January 2003 on the
restriction of the use of certain hazardous substances in
electrical and electronic equipment
TUV Certifi cate
CDRH compliant and Class 1 laser eye safe
Noise frequency range: 30 MHz to 40 GHz.
Good system EMI design practice required
to achieve Class B margins.
Exceeds requirements. Withstand discharges of;
8kV contact, 25kV air
Exceeds requirements. Field strength of 10 V/m RMS,
from 10 MHz to 1 GHz. No effect on transmitter / receiver
performance is detectable between these limits.