1382350-1 TE Connectivity, 1382350-1 Datasheet - Page 6

no-image

1382350-1

Manufacturer Part Number
1382350-1
Description
Manufacturer
TE Connectivity
Datasheet

Specifications of 1382350-1

Optical Fiber Type
TX/RX
Data Transfer Rate
1250Mbps
Optical Rise Time
0.26ns
Optical Fall Time
0.26ns
Jitter
0.08ns
Operating Temperature Classification
Commercial
Peak Wavelength
845nm
Package Type
SFP MSA
Operating Supply Voltage (min)
3.135V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.465V
Operating Temp Range
0C to 70C
Mounting
Snap Fit To Panel
Lead Free Status / RoHS Status
Supplier Unconfirmed
6
©
For drawings, technical data or samples, contact your Tyco Electronics sales engineer, call 1-800-522-6752, or visit our Website at:
http://www.tycoelectronics.com/fiberoptics. Specifications subject to change. Consult Tyco Electronics for latest specifications.
NOTE 1: Transmitter and receiver grounds are connected together inside the transceiver module.
NOTE 2: Pull-up voltage between 2.0V and VccT + 0.3V
NOTE 3: V
Pad Description:
Copyright 2003 by Tyco Electronics Corporation. All Rights Reserved. AMP and Tyco are trademarks. Dimensions are in millimeters with inches
(if shown) in brackets. Other products, logos, and Company names mentioned herein may be trademarks of their respective owners.
MOD-DEF2
MOD-DEF1
MOD-DEF0
Rate Select
Tx_Disable
Tx_Fault
Symbol
CC
V
V
V
V
V
V
V
V
V
LOS
RD+
TD+
RD-
TD-
CC
EE
EE
EE
EE
CC
EE
EE
EE
T and V
R
R
R
R
R
T
T
T
T
CC
R are separate inside the transceiver module.
Gigabit Ethernet Multimode SFP MT-RJ Transceiver
Pad #
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
Signal Ground. Directly connect to ground. [SEE NOTE 1].
Transmitter Fault. This is an open collector output that should be pulled up with a
4.7K - 10KΩ resistor on the host board. [SEE NOTE 2].
Transmitter Disable Input. Module disables on high or open. The input is pulled up
within the module with a 4.7K - 10KΩ resistor. Its states are:
Low (0 - 0.8V) :
(>0.8, <2.0V) :
High (2.0 - 3.465V) :
Open:
Module Definition 2. This is the data line of two wire serial interface for serial ID.
This pad should be pulled up with a 4.7K - 10KΩ resistor on the host board.
[SEE NOTE 2].
Module Definition 1. This is the clock line of two wire serial interface for serial ID.
This pad should be pulled up with a 4.7K - 10KΩ resistor on the host board.
[SEE NOTE 2].
Module Definition 0. MOD-DEF0 is grounded by the module to indicate that the
module is present. The pad should be pulled up with a 4.7K - 10KΩ resistor on the
host board. [SEE NOTE 2].
This function is not implemented and the pad is floating. Per the SFP MSA, this is
an optional input used to control the receiver bandwidth for multiple data rate
operation.
Loss of Signal. This is an open collector output that should be pulled up with a
4.7K - 10KΩ resistor on the host board. [SEE NOTE 2]. Normal operation is when
LOS is Deasserted. Abnormally low receive signal level is indicated by LOS
Asserted.
Signal Ground. Directly connect to ground. [SEE NOTE 1].
Signal Ground. Directly connect to ground. [SEE NOTE 1].
Signal Ground. Directly connect to ground. [SEE NOTE 1].
Received Data Out Bar. Output is internally AC coupled. Use SerDes chip IC
manufacturer's termination recommendation to achieve a 50 Ω termination
impedance.
Received Data Out. Output is internally AC coupled. Use SerDes chip IC
manufacturer's termination recommendation to achieve a 50 Ω termination
Signal Ground. Directly connect to ground. [SEE NOTE 1].
Receiver Power Supply. Connect as shown in the Recommended Host Board
Supply Filtering Network. [SEE NOTE 3].
Transmitter Power Supply. Connect as shown in the Recommended Host Board
Supply Filtering Network. [SEE NOTE 3].
Signal Ground. Directly connect to ground. [SEE NOTE 1].
Transmitter Data In. Input is internally AC coupled. There is an internal 100 Ω
resistor across TD+ and TD-, which provides a 50 Ω termination for each data input.
Transmitter Data In Bar. Input is internally AC coupled. There is an internal 100 Ω
resistor across TD+ and TD-, which provides a 50 Ω termination for each data input.
Signal Ground. Directly connect to ground. [SEE NOTE 1].
impedance.
Transmitter on
Undefined
Transmitter Disabled
Transmitter Disabled.
Function
(Continued)
http://www.tycoelectronics.com/fiberoptics
PDF Datasheet 1654843
Only available as PDF at:
Revised 11-03