MC10XS3412CPNA Freescale, MC10XS3412CPNA Datasheet - Page 41

no-image

MC10XS3412CPNA

Manufacturer Part Number
MC10XS3412CPNA
Description
Manufacturer
Freescale
Datasheet

Specifications of MC10XS3412CPNA

Switch Type
High Side
Power Switch Family
MC10XS3412
Input Voltage
4 to 28V
Power Switch On Resistance
36/44Ohm
Output Current
6A
Number Of Outputs
4
Mounting
Surface Mount
Supply Current
6.5mA
Package Type
PQFN
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Pin Count
24
Lead Free Status / RoHS Status
Compliant
PREVIOUS ADDRESS SOA4 : SOA0 = A
(CONFR0_S)
CONFR0 register for the output selected with A
PREVIOUS ADDRESS SOA4 : SOA0 = A
(CONFR1_S)
CONFR1 register for the output selected with A
PREVIOUS ADDRESS SOA4 : SOA0 = A
(OCR_S)
OCR register for the output selected with A
PREVIOUS ADDRESS SOA4 : SOA0 = 00101 (GCR)
GCR register.
PREVIOUS ADDRESS SOA4 : SOA0 = 00111
(DIAGR0)
clock on IN0 pin is out of specified frequency range.
calibration failure.
temperature prewarning (temperature of GND flag is above
T
PREVIOUS ADDRESS SOA4 : SOA0 = 01111
(DIAGR1)
of the direct input IN[3:0].
Analog Integrated Circuit Device Data
Freescale Semiconductor
OTWAR
The returned data contains the programmed values in the
The returned data contains the programmed values in the
The returned data contains the programmed values in the
The returned data contains the programmed values in the
The returned data OD2 reports logic [1] in case of PWM
The returned data OD1 reports logic [1] in case of
The returned data OD0 reports logic [1] in case of over-
The returned data OD4: OD1 report in real time the state
).
1
A
1
1
1
0
A
A
A
.
1
1
0
A
0
A
0
010
011
100
0
0
.
.
[1]) or not (set to logic [0]). OD4:OD1 report the output state
in case of Fail-safe state due to watchdog timeout as
explained in the following
PREVIOUS ADDRESS SOA4 : SOA0 = 10111
(DIAGR2)
to 000 for Protected Dual 10 mΩ and 12 mΩ High Side
Switches.
DEFAULT DEVICE CONFIGURATION
• HS output is commanded by corresponding IN input or On
• HS output is fully protected by the Xenon over-current
• Open-load in ON and OFF state and HS shorted to VPWR
• No current recopy and no analog temperature feedback
• Over-voltage protection is enabled,
• SO reporting fault status from HS0,
• VDD failure detection is disabled.
Table 24. Watchdog Activation Report
The OD0 indicates if the watchdog is enabled (set to logic
The returned data is the product ID. Bits OD2:OD0 are set
bit through SPI. The medium slew rate is used,
profile by default, the severe short-circuit protection, the
under-voltage and the over-temperature protection. The
auto-retry feature is enabled,
detections are available,
active,
WD_en (OD0)
The default device configuration is explained below:
0
1
LOGIC COMMANDS AND REGISTERS
Table
FUNCTIONAL DEVICE OPERATION
24.
SPI Watchdog
disabled
enabled
10XS3412
41

Related parts for MC10XS3412CPNA