FC100V5A POWER ONE, FC100V5A Datasheet - Page 33

FILTER 5 AMP PC MOUNT

FC100V5A

Manufacturer Part Number
FC100V5A
Description
FILTER 5 AMP PC MOUNT
Manufacturer
POWER ONE
Series
FCr
Datasheet

Specifications of FC100V5A

Filter Type
Power Line
Voltage - Rated
100V
Current
5A
Mounting Type
Through Hole
Termination Style
PCB Pins
Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
85C
Rad Hardened
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Inductance
-
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Not Compliant
Other names
179-2178

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FC100V5A
Manufacturer:
POWER-O
Quantity:
20 000
Part Number:
FC100V5A
Quantity:
55
Company:
Part Number:
FC100V5A
Quantity:
690
Electrical Specifications
Conditions: T
Additional Notes:
MCD10059 Rev. 1.1, 21-Jan-10
Electrical Characteristics
Absolute Maximum Ratings
Input Voltage
Operating Ambient Temperature
Storage Temperature
Operating Input Voltage Range
Maximum Operating Current
Voltage Drop at Maximum Load
Voltage Drop – Typical Application
Efficiency at Typical Load
Conducted Noises, Quasi-Peak Level
- Main frequency and low harmonics up
- High frequencies up to 30 MHz
to 5 MHz
1.
2.
3.
4.
5.
Absolute maximum voltage and maximum operating voltage are for the filter itself; check maximum rating for corresponding
DC-DC converters. Filter will not be damaged with reversed input voltage.
Designed primarily for 48 V applications, filter can be used with both 48 V converters (operating range from 36 V to 72 V) and
24 V converters (operating range from 18 V to 36 V). Typical filter application schematic is shown on Fig. 1.
Maximum current at any ambient temperature without airflow can be calculated as Imax = [4 - 0.025*(Tamb-45)] A, with
constraint Imax ≤ 4 A.
Letter x denotes either T or S, i.e. filter module is loaded either with Q48T30033 through-hole or Q48S30033 surface
mounted converter.
Typical EMI plot for conducted emissions (with fully loaded Q48x30033 converter connected to the filter output, see
schematic Fig. 1) is shown on Fig. 2. Plot was taken by independent test laboratory TUV. TUV report confirms compliance
with Class B requirements according EN-55022 (CISPR-22) and FCC standards.
A
1
=25 ºC, No Airflow, Vin=48 VDC, unless otherwise specified.
Parameter
1, 2
5
Continuous
85 °C ambient, no airflow
85 °C ambient, airflow 300 LFM [1.5 m/s]
Loaded with Q48x30033 (3.3 V, 30 A)
Loaded with Q48x30033 (3.3 V, 30 A)
4 A
Loaded with Q48x30033 (3.3 V, 30 A)
F & FC Series DC-DC Converter Input Filters
Page 33 of 41
Notes
3
F4804, Not for New Designs
4
Min
99.6
-40
-55
0
0
Typ
0.16
99.7
48
40
35
www.power-one.com
Max
0.32
100
125
85
80
45
48
3
4
Units
dBμV
dBμV
VDC
VDC
ADC
ADC
VDC
VDC
°C
°C
%

Related parts for FC100V5A